Festo — VTSA-F-CB — 2021-06a
Parameterisation
69
Byte
Bit
Description
Process output data
0
7 … 1
reserved
0
–
0: valve switched off
–
1: valve switched on
Tab. 44: Process data of the pilot air switching valves with M12 connection
Process data of the pneumatic interfaces
The process data belong to the following type codes:
–
VABA-S6-1-X1-CB, VABA-S6-1-X2-CB
–
VABA-S6-1-X1-3V-CB, VABA-S6-1-X2-3V-CB
–
VABA-S6-1-X2-F1-CB, VABA-S6-1-X2-F2-CB
–
VABF-S6-1-P8A7-G12-CB, VABF-S6-1-P8A7-G12-CB1
–
VABF-S6-1-P8A6-G12-CB, VABF-S6-1-P8A6-G12-CB1
Byte
Bit
Description
Process input data
2
23 … 16
Solenoid coils SP23 … SP16
1
15 … 8
Solenoid coils SP15 … SP8
0
7
SP7
6
SP6
5
SP5
4
SP4
3
SP3
2
SP2
1
SP1
0
SP0=0: duct error (short circuit or wire break)
SP0=1: error-free operation
Process output data
2
23 … 16
Solenoid coils SP23 … SP16
1
15 … 8
Solenoid coils SP15 … SP8