7
The power cord line is not included with stand-alone Phase-Coded Pulse Compression Processor. Please add the right power cord line for the
region. Note that when ordering a system, all power cord lines are included.
8
The power cord line is not included with stand-alone Phase-Coded Pulse Compression Processor. Please add the right power cord line for the
region. Note that when ordering a system, all power cord lines are included.
9
The power cord line is not included with stand-alone Phase-Coded Pulse Compression Processor. Please add the right power cord line for the
region. Note that when ordering a system, all power cord lines are included.
Radar Training System, LabVolt Series
© Festo Didactic
34
Parameter
Value
Trigger Output
TTL
X and Y Outputs
-5 V to +5 V
Interface to SAR Processor
USB
Physical Characteristics
Dimensions (H x W x D)
8 x 14 x 19 mm (3.2 x 5.5 x 7.5 in)
Net Weight
1.1 kg (2.4 lb)
Phase-Coded Pulse Compression Processor
592571 (9615-00)
The Phase-Coded Pulse Compression Processor allows to
experiment pulse compression with the radar training system. It
is divided into three sections: Dual-Channel Sampler, Pulse
Compressor and Pulse Generator.
The Dual-Channel Sampler samples the I- and Q-Channel
baseband signals from the receiver and stretch these signals in
time in order to facilitate observation and measurement. It also
allows to set the origin (radar display "window") and select the
range span. A time base output is available to trig an
oscilloscope when displaying the A-Scope.
The Pulse Compressor compresses the pulses by correlating the
digital data with the selected code using one or two compressor
stages. It allows to select the sample rate of the A/D converter,
select the filter mode (matched or optimum mismatched). Test points are also available to monitor the different
signals using an oscilloscope.
The PRF and Sync. signals need to be inputted into the module. Note that only the 288 Hz PRF mode is
supported.
The Pulse Generator allows to select the pulse compression code used to encode the baseband pulse.
A switch at the back of the module allows to inject noise into the system to experiment real-life conditions.
Additional Equipment Required to Perform the Exercises
Qty Description
Model
number
1
Power Cord - Type F ____________________________________________________________ 789182 (93992-05)
7
1
Power Cord - Type B ___________________________________________________________ 789405 (95451-00)
8
1
Power Cord - Type I ____________________________________________________________ 789406 (95451-0A)
9