4
Mounting
Festo – EXCM-40-EN – 2017-11a – English
33
1. Unscrew the screws
2
.
2. Remove the retaining plate
8
and the cover
3
.
3. Unscrew the screw
5
and loosen the earthing cable.
4. Unscrew the screws
7
and remove the earthing component
6
.
5. Unscrew the screws
9
and remove the cross plate
aJ
.
6. Remove all of the cable ties
4
.
7. Push the guide plate
1
with the energy chain in the direction of the arrow.
è
The sensor slot
aB
is accessible.
8. Remove the cable clamp
aE
.
9. Insert the proximity sensor
aC
into the sensor slot
aB
.
10.Align the proximity sensor
aC
flush with the outer edge of the adapter plate
aD
.
11.Secure the proximity sensor
aC
with the supplied screw (tightening torque 0.3 Nm).
12.Insert the cable of the proximity sensor into the slot
aF
.
13.Mount the cable clamp
aE
with the 2 screws (tightening torque 1.2 Nm).
è
The cable is routed within the slots
aB
and
aF
.
14.Insert the plug connecter of the proximity sensor into the multi-pin plug distributor
aA
(
è
4
).
15.Position the guide plate
1
with the energy chain.
16.Position the cross plate
aJ
.
17.Tighten the screws
9
with Loctite 243 adhesive (tightening torque 4.0 Nm).
18.Position the earthing component
6
.
19.Tighten the screws
7
with Loctite 243 adhesive (tightening torque 1.2 Nm).
20.Secure the earthing cable to the earthing component
6
with screw
5
(tightening torque 1.2 Nm).
21.Secure the cables between the energy chains with cable ties
4
for strain relief.
22.Position the cover
3
and retaining plate
8
.
23.Tighten the screws
2
(tightening torque 1 Nm).