4
Mounting
Festo – EXCM-40-EN – 2017-11a – English
31
4.7
Accessories
Select suitable accessories from the Festo catalogue
(
è
www.festo.com/catalogue).
Observe the assembly instructions for the accessories.
4.7.1
X-axis proximity sensor
The proximity sensor detects the position of the
Y-axis (traverse)
2
.
A sensor mount
1
is also required for mounting
the proximity sensor (not included in the scope of
delivery). The sensor mounting and the proximity
sensor can be moved on the X-axis.
1
2
Fig. 4.30
4.7.2
Y-axis (traverse) proximity sensor
The proximity sensor detects the position of the
slide on the Y-axis
3
The slot for mounting the proximity sensor is loc
ated in the slide of the Y-axis
3
.
The 2 switch lugs
1
for actuation of the proximity
sensor are mounted under the cover of the Y-axis
(traverse)
2
.
The positions of the proximity sensor and the
switch lugs cannot be changed.
1
2
3
Fig. 4.31