34 / 56
Festo 7DSBCa_en
3. Screw in the flange screws.
4. Align the holder of the clamping unit flush with the bearing cap.
5. Tighten the flange screws with the appropriate tightening torque.
Size
Tightening torque
DSBC-32
5 Nm
DSBC-40
5 Nm
DSBC-50
10 Nm
DSBC-63
10 Nm
DSBC-80
25 Nm
DSBC-100
25 Nm
DSBC-125
35 Nm
6. Remove the mounting screw from the supply port.
Further steps:
.