![Festo CPV GEASI-4 Series Brief Description Download Page 6](http://html1.mh-extra.com/html/festo/cpv-geasi-4-series/cpv-geasi-4-series_brief-description_2284143006.webp)
Festo CPV..-GE-ASI-... 2017-11e English
6
3.3 Address assignment of the valves (top view)
The following equipm. may be fiitted on the valve terminal:
Equipment in the valve locations
4 single-solenoid valves 2 double-solenoid
valves
1 double-solenoid valve
2 single-solenoid valves
[J 1 2
6 6 6 6
3
4
4
[J
2
7 8 7 8
4
5
1
3
5
4
[J
2
7 8 6 6
3
4
5
1
5
4
Permitted DIP switch settings (see section 4.5)
1: OFF
2: ON
3: OFF
4: ON
1: ON
2: OFF
3: ON
4: OFF
1: ON
2: OFF
3: OFF
4: ON
[J
...
3
Addresses of the solenoid coils for the AS-Interface address
4
Addresses or LEDs of solenoid coils 14
5
Addresses or LEDs of solenoid coils 12
6
Valve plates with 1 valve solenoid coil (e.g. code M, F, A)
*)
7
Valve plates with 2 valve solenoid coils, such as 2 single-
solenoid valves, 5/2-way double-solenoid valves or 5/3-way
valves (e.g. J, N, C, H, G, D, I, E)
*)
8
Only blanking plate or separator plate permitted
(e.g. code L, S, T)
*)
Or blanking plate or separator plate