Service life
Service life of the
device with rated load
in S1 operation
1)
and
40 °C ambient temper-
ature
[h]
25,000
Service life of the
device with
<
50 %
rated load in S1 opera-
tion
1)
and 40 °C ambi-
ent temperature
[h]
50,000
1) Continuous operation with constant load
Tab. 22 Service life
9.4
Technical data, electrical
9.4.1
Motor auxiliary connection [X6B]
Output of holding brake [X6B]
CMMT-AS-
C2-3A
C4-3A
Design
High-side switch
1)
Max. continuous out-
put current
[A]
1
Max. voltage drop from
+ 24 V input at connec-
tion [X9A] to brake out-
put at [X6B]
[V DC]
0.8
Max. permissible
inductive load
[H]
<
5
Protective functions
–
Short circuit to 0 V/PE
–
Overvoltage-proof to 60 V
2)
–
Thermal overload protection
Fault detection
Voltage at output despite brake having shut down
Diagnostics possible via:
–
Output SBA
–
Error message on device
1) The test pulses of the associated control input #SBC-A are mapped to the output subject to a switching delay.
2) Brake output also shuts down in the event of a fault if there is an overvoltage on the logic supply.
Tab. 23 Output of holding brake [X6B], 1-phase devices
Technical data
38
Festo — CMMT-AS-...-S1 — 2018-10a