UL/CSA certification information
UL mark
UL control number
4PU8
Tab. 63: UL/CSA certification information
–
Use in an environment with pollution degree 2 (or better).
–
Use only Cu cables that have a permissible constant insulation temperature of
at least 75 °C at the following connections:
–
[X6A], motor connection
–
[X9A], power supply and DC link circuit connection
–
[X9B], connection for braking resistor
–
[X9C], logic voltage supply
–
CMMT-AS-C7/C12-11A-P3-...-S1 is suitable for the following power supply net-
works:
–
Type WYE 480 V/277 V with a short circuit current rating of SCCR 10 kA
For operation in type WYE 480 V/277 V power supply networks with
SCCR > 10 kA
è
Manual assembly, installation.
–
Permissible and impermissible mains types of system earthing:
–
According to the UL standard, the TT system with separate neutral conductor
and PE conductor is not permitted in the overall system.
–
UL: The integrated semiconductor short-circuit protection does not protect the
downstream power circuit. The power circuit must be protected in conformity
with the National Electrical Code and all other local regulations.
CSA: The integrated semiconductor short-circuit protection does not protect the
downstream power circuit. The power circuit must be protected in conformity
with the Canadian Electrical Code, part I.
Requirements for circuit breakers (automatic circuit breakers) and fuses
Overcurrent protective device
Circuit breaker
max. permissible rated cur-
rent
[A]
30
Short circuit current rating
SCCR of mains fuse
[kA]
min. 10
Rated voltage
[V AC]
480
Tab. 64: Requirements for circuit breakers and fuses
13.5
Additional technical data
Additional technical data on the product and detailed descriptions of all interfaces
è
Manual Assembly, Installation.