![Festo CMMS-ST-*-G2 Series Assembly And Installation Manual Download Page 122](http://html1.mh-extra.com/html/festo/cmms-st-g2-series/cmms-st-g2-series_assembly-and-installation-manual_2283131122.webp)
8. Service functions and error messages
122
Festo.P.BE-CMMS-ST-G2-HW-EN
1008NH
Display Meaning
PH x
Homing run. “x” represents the respective phase of the homing run:
0: Search phase
1: Slow moving phase
2: Travel to zero position
The digits are sequentially displayed
E xxy
Error message with index “xx” and sub-index “y”
-xxy-
Warning message with index “xx” and sub-index “y”. Warnings are shown at least
twice on the seven-segment display.
Table
8.1 Operating mode and error display
8.2.2
Error messages
When a fault occurs, the CMMS-ST displays an error message cyclically in the seven
segment display. The error message consists of an E (for error), a main index and sub-
index, e.g.: E 01 0.
The meaning and the measures for the error messages are compiled in the table below:
Error message
Main
index
Sub-
index
Meaning of error
message
Measures Error
reaction
01
0
Stack overflow
Wrong firmware?
Reload standard firmware if necessary.
Contact Technical Support.
PS off
02 0 Undervoltage
in intermediate circuit
Undervoltage monitoring is configured
using the FCT.
Measure intermediate circuit voltage.
Check configuration.
PS off
1)
0 Motor
temperature
monitoring
Motor too hot?
Check parameters (current regulator,
current limits)
Correct sensor?
Cable broken?
Sensor defective?
If the error remains even when the sensor
is bridged: device defective.
PS off
03
1 Motor
temperature
monitoring
Fault in dig. motor temperature sensor
PS off
1)
04 0 Over-/under-temperature
in power electronics
Temperature display plausible?
Check installation conditions (cooling: via
the housing surface, the integrated heat
sink and back wall).
PS off
1)