Parameters
Value
Max. Operating pressure in piping
50 kPa (0.5 bar)
Power supply for station
24 V DC/4.5 A
Profile plate
700 x 700 x 32 mm
Pump flow rate
0 - 6 l/min
Container volume
10 l max.
Flexible piping system
DN15 (
∅
a
15 mm)
Digital inputs
4
Digital outputs
5
Analogue inputs
1
Analogue outputs
1 (2)
Number of containers
1
Signal range of final control
elements
Heating unit (capacity 0 -
1000 W)
230 V AC
0 - 10 V
(control voltage 24 V DC)
Pumps (0 - 24 V DC)
On/Off
0 - 10 V
(control voltage 24 V DC)
Stirrer (0 - 24 V DC) with gear
unit
Analogue actuation of the stirrer
is also possible.
On/Off
(control voltage 24 V DC)
0 - 10 V
Operating range of temperature control system
0° C - +60° C
Measuring range of temperature control sensor
-50° C - 150° C
Signal of sensor for temperature control system
Resistor PT100
3