3.4 FAULTS
The heater is equipped with an advanced self-diagnostic system. If a problem arises with
the unit, the fault symbol will flash on the screen and the respective code will be displayed.
Some faults, identified with the letter “A,” will block unit operation.
To restore operation, simply press the RESET key (4 - fig. 1) for 1 second. If the heater
does not reset, the fault must be resolved.
Faults identified by the letter “F” cause temporary blocks that are automatically resolved
when the value returns to the heater's normal operating range.
3.4.1 LIST OF FAULTS
Fault code
Fault
Possible cause
Solution
A01
The burner does not
ignite.
Lack of gas
Make sure gas is
flowing properly to the
heater, and no air is
present in the pipes.
Faulty detection/
ignition electrode
Make sure the
electrode is properly
installed, connected,
and free of deposits.
Faulty gas valve
Check the gas
valve and replace if
necessary.
Gas valve wiring
interrupted
Check the wiring.
Ignition power too
low
Adjust the ignition
power.
A02
Flame signal present
while the burner is off
Faulty electrode
Check the ionization
electrode wiring.
Faulty card
Check the card.
A03
Protection activated
Faulty DHW sensor
Check the position
and operation of the
DHW sensor.
No water is
circulating.
Check the flow switch.
A06
No flame is present after
the ignition phase.
Low pressure on the
gas network
Check the gas
pressure.
Minimum burner
pressure adjustment
Check the pressures.
A09
Faulty gas valve
Wiring interrupted
Check the wiring.
Faulty gas valve
Check the gas
valve and replace if
necessary.
A16
Faulty gas valve
Wiring interrupted
Check the wiring.
Faulty gas valve
Check the gas
valve and replace if
necessary.
A21
Bad combustion fault
Fault F20 generated
6 times in the last
10 minutes
See fault F20.
A41
Sensor position
DHW sensor
detached from the
pipe
Check the position
and operation of the
sensor.
A51
Bad combustion fault
Obstruction of
the aspiration/
evacuation duct
Check the flue.
F04
Card setting fault
Incorrectly
configured card
setting
Check the card
setting and change if
necessary.
F05
Card setting fault
Incorrectly
configured card
setting
Check the card
setting and change if
necessary.
Faulty fan
Wiring interrupted
Check the wiring.
Faulty fan
Check the fan.
Faulty card
Check the card.
F07
Card setting fault
Incorrectly
configured card
setting
Check the card
setting and change if
necessary.
Fault code
Fault
Possible cause
Solution
F10
Faulty DHW 1 sensor
Defective sensor
Check the wiring or
change the sensor.
Short-circuited
wiring
Wiring interrupted
F14
Faulty DHW 2 sensor
Defective sensor
Check the fan and the
respective wiring.
Short-circuited
wiring
Wiring interrupted
F20
Combustion control fault
Faulty fan
Check the fan and the
respective wiring.
Incorrect diaphragm
Check the diaphragm
and replace if
necessary.
Flue badly sized or
obstructed
Check the flue.
F34
Supply voltage under
180 V.
Problems in the
electrical network
Check the electrical
installation.
F42
Faulty DW sensor
Defective sensor
Change the sensor.
F50
Faulty gas valve
Modulating actuator
wiring interrupted
Check the wiring.
Faulty gas valve
Check the gas
valve and replace if
necessary.
48
EN
SKY ECO F
code A73022090
Summary of Contents for SKY ECO F 11
Page 11: ...4 5 Schema elettrico fig 18 Dimensioni e attacchi 11 IT SKY ECO F cod A73022090...
Page 21: ...4 5 Esquema el ctrico fig 18 Dimensiones y conexiones 21 ES SKY ECO F cod A73022090...
Page 31: ...4 5 Schema electric fig 18 Dimensiuni i racorduri 31 RO SKY ECO F cod A73022090...
Page 41: ...4 5 Schemat elektryczny Rys 18 Wymiary i pod czenia 41 PL SKY ECO F Nr kat A73022090...
Page 51: ...4 5 Wiring diagram fig 18 Dimensions and connections 51 EN SKY ECO F code A73022090...