For connection to separate Ø80 pipes, vertical pipe with condensate collection
(1KWMA5500).
2.7.3 Connection with coaxial pipes
C1x
- Horizontal aspiration and evacuation on the wall
C3x
- Vertical aspiration and evacuation on the ceiling
= Air
= Flue gases
fig. 12 - Example of a connection with coaxial pipes
Coaxial 60/100
Coaxial 80/125
Maximum permitted length
4 m
10 m
Elbow reduction factor 90°
1 m
0,5 m
Curve reduction factor 45°
0,5 m
0,25 m
Diaphragm to be used
0 to 2 m
SKY ECO F 11 =
Ø40
SKY ECO F 14 =
Ø47
SKY ECO F 17 =
Ø50
0 to 3 m
SKY ECO F 11 =
Ø40
SKY ECO F 14 =
Ø47
SKY ECO F 17 =
Ø50
2 to 3 m
SKY ECO F 11 =
Ø43
SKY ECO F 14 =
Ø50
SKY ECO F 17 =
Ø52
3 to 6 m
SKY ECO F 11 =
Ø43
SKY ECO F 14 =
Ø50
SKY ECO F 17 =
no diaphragm
3 to 4 m
no diaphragm
6 to 10 m
no diaphragm
For the coaxial connection, install one of the following initial accessories on the unit. For
drilling dimensions on the wall, see section 4.1. Horizontal exhaust segments must slope
slightly toward the outside to prevent any condensation from returning to the unit.
fig. 13 - Initial accessories for coaxial ducts
2.7.4 Connection with separate pipes
fig. 14 - Example of a connection with separate pipes
C1x
Horizontal aspiration and evacuation on the wall. Intake and exhaust terminals must
be concentric, or close enough to be exposed to similar wind conditions (maximum
distance of 50 cm).
C3x
Vertical aspiration and evacuation on the ceiling. Intake/exhaust terminals suitable
for C12.
C5x
Separate aspiration and evacuation on the wall or ceiling or, in any case, in areas
under different pressure. Aspiration and evacuation may not be placed on opposite
walls.
C6x
Aspiration and evacuation with separate certified pipes (EN 1856/1).
B2x
Aspiration from the installation environment and evacuation on the wall or ceiling.
= Air
= Flue gases
IMPORTANT - THE ROOM MUST BE EQUIPPED WITH APPROPRIATE
VENTILATION.
To connect the separate ducts, install the following initial accessory on the unit:
fig. 15 - Initial accessory for separate ducts, code 010031X0 / 4740
Table 2
Model
Length
Diaphragm
Maximum permitted
length
SKY ECO F 11
65 m
eq
SKY ECO F 14
55 m
eq
SKY ECO F 17
45 m
eq
Diaphragm to be used
SKY ECO F 11
0 - 35 m
eq
Ø 40
35 - 65 m
eq
no diaphragm
SKY ECO F 14
0 - 30 m
eq
Ø 47
30 - 55 m
eq
no diaphragm
SKY ECO F 17
0 - 25 m
eq
Ø 50
25 - 45 m
eq
no diaphragm
46
EN
SKY ECO F
code A73022090
Summary of Contents for SKY ECO F 11
Page 11: ...4 5 Schema elettrico fig 18 Dimensioni e attacchi 11 IT SKY ECO F cod A73022090...
Page 21: ...4 5 Esquema el ctrico fig 18 Dimensiones y conexiones 21 ES SKY ECO F cod A73022090...
Page 31: ...4 5 Schema electric fig 18 Dimensiuni i racorduri 31 RO SKY ECO F cod A73022090...
Page 41: ...4 5 Schemat elektryczny Rys 18 Wymiary i pod czenia 41 PL SKY ECO F Nr kat A73022090...
Page 51: ...4 5 Wiring diagram fig 18 Dimensions and connections 51 EN SKY ECO F code A73022090...