PCB A, Inverter board for 1 phase 5,7kw unit.
1
4
5
6
7
3
8
9
10
11
2
1-phase 5/7kW
1 To main board (CN101,CN105)
2 Compressor connection port U V W (U,V,W)
3 Input port N for IPM module(N)
4 Input port P for IPM module(P)
5 Input port for PFC inductance P1(P1)
6 Input port for bridge Rectifiers(P5)
7 Input port for Bridge Rectifiers(P6)
8 Output port P of PFC(P2)
9 Input port for PFC inductance 3(P3)
10 Output port N of PFC(P4)
11 +18V(P9)
PCB A, Inverter board for 1-phase Mod . 5-7
1 To main board (CN101,CN105)
2 Compressor connection port U V W (U,V,W)
3 Input port N for IPM module(N)
4 Input port P for IPM module(P)
5 Input port for PFC inductance P1(P1)
6 Input port for bridge Rectifiers(P5)
7 Input port for Bridge Rectifiers(P6)
8 Output port P of PFC(P2)
9 Input port for PFC inductance 3(P3)
10 Output port N of PFC(P4)
11 +18V(P9)
25
1 Rectifier bridge input port L
2 Hydraulic compartment input port2
3 Rectifier bridge input port N
4 Power supply N
5 Power supply L
6 Transformer output port
7 BLACK: T3 temperature sensor port
WHITE:T4 temperature sensor port
8 TP temperature sensor port
9 YELLOW: High pressure switch
RED: Low pressure switch
10 Th temperature sensor port
11 Pressure sensor port
12 Wire controller port
13 P/N/+18V port
14 To IPDU/PFC
15 DC fan port
16 Compression electromechanical
heating belt
17 4-way valve port
18 Transformer input port
1-phase 5/7kW
PCB B, Main control board for 1 phase 5,7kw unit.
PCB A
2
4
5
6
7
8
9
10
11
12
13
15
14
16
17
18
3
1
Summary of Contents for RVL-I PLUS
Page 31: ...31 SETUP OF THE SYSTEM...
Page 32: ...32 SETUP OF THE SYSTEM...
Page 33: ...33 SETUP OF THE SYSTEM...
Page 34: ...34 SETUP OF THE SYSTEM FOR SEVICEMAN menu english language...
Page 35: ...35 SETUP OF THE SYSTEM...
Page 36: ...36 SETUP OF THE SYSTEM...
Page 37: ...37 SETUP OF THE SYSTEM...
Page 91: ...91...