49
SETUP OF THE SYSTEM
To restore factory settings, go to MENU> FOR SERVICEMAN> RESTORE FACTORY
SETTINGS . Press OK . The following page is displayed:
To enter test run, go to MENU> FOR SERVICEMAN> TEST RUN . Press OK . The fol-
lowing page is displayed:
If YES is selected, the following page is displayed:
Use ▼ ▲ to scroll to the mode you want to run and press
OK . The unit will run as selected .
If 12 .1 POINT CHECK is selected, the following page will
not be displayed:
Use ◄ ► to scroll the cursor to YES and press OK. the following page will be displayed:
After a few seconds, all the parameters set in the user interface will be restored to factory settings
Restore factory settings
The RESTORE FACTORY SETTING is used to restore all the parameters set in the
user interface to the factory setting .
Test run
TEST RUN is used to check correct operation of the valves, air purge, circulation pump operation, cooling, heating and domestic
water heating .
11 RESTORE FACTORY SETTINGS
All the settings will revert to
factory default. Do you want to
restore factory setting?
SCROLL
CONFIRM
OK
NO
YES
11 RESTORE FACTORY SETTINGS
Please wait…
5%
12 TEST RUN
Activate the settings and
activate “TEST RUN”?
SCROLL
CONFIRM
OK
NO
YES
12 TEST RUN
AIR PURGE
CIRCULATION PUMP RUNNING
COOL MODE RUNNING
HEAT MODE RUNNING
DHW MODE RUNNING
12.1 POINT CHECK
SCROLL
ENTER
OK
12.1 POINT CHECK
2-WAY VALVE
PUMP1
PUMP0
PUMP0
PUMPSOLAR
3-WAY VALVE
OFF
OFF
OFF
OFF
OFF
OFF
SCROLL
ON/OFF
ON/OFF
12.1 PIONT CHECK
BACKUP HEATER1
BACKUP HEATER2
TANK HEATER
PUMPDHW
OFF
OFF
OFF
OFF
SCROLL
ON/OFF
ON/OFF
Summary of Contents for RVL-I PLUS
Page 31: ...31 SETUP OF THE SYSTEM...
Page 32: ...32 SETUP OF THE SYSTEM...
Page 33: ...33 SETUP OF THE SYSTEM...
Page 34: ...34 SETUP OF THE SYSTEM FOR SEVICEMAN menu english language...
Page 35: ...35 SETUP OF THE SYSTEM...
Page 36: ...36 SETUP OF THE SYSTEM...
Page 37: ...37 SETUP OF THE SYSTEM...
Page 91: ...91...