Fig. 13
3. SERVICE AND MAINTENANCE
3.1 Adjustments
All adjustment and conversion operations must be carried out by Qualified Personnel such as Local Technical
Assistance Service personnel.
Ferroli
declines any liability for damage or injury caused by unqualified and unauthorized persons tampering
with the appliance.
Gas conversion
The unit can run on Natural Gas or LPG and is factory-set for use with one of the two gases, as clearly
shown on the packing and on the appliance dataplate. Whenever a different gas to that for which the unit
is preset has to be used, a conversion kit will be required, proceeding as follows:
1
Unscrew the gas fittings
A
located on the air/gas mixers
B
.
2
Change the nozzles in the mixers with those contained in the conversion kit.
3
Refit the fittings
A
and check that the connections are tight.
4
Apply the sticker contained in the conversion kit, near the dataplate.
NB:
For the nozzle sizes, see the technical data table