7
ECONCEPT 100
20
30
40
50
60
70
80
90
20
10
0
-10
-20
Outside temperature °C
System delivery temperature C°
1
2
3
4
5
6
7
8
9
10
Adjustments
Setting the system temperature
To set the system delivery temperature on the single boiler shell, access the operational menu and press
the
key to display parameter 1 - system delivery temperature. On pressing one of the
keys, the
display starts flashing and the delivery temperature setpoint is displayed. Set the required value with the
keys. To activate the new setting, press the
key. To cancel, do not press
and press
.
Summer/Winter selection
For the Summer/Winter selection, access the operation menu and press
to display the parameter “0.”.
At parameter “0.”, press one of the
keys to display the Summer/Winter selection (the parameter “0.”
flashes); by using the same keys it is possible to select Summer mode (set 00) or Winter mode (set 11). To
activate the new setting, press
; to exit without activating the selection, press
.
In “Summer” mode (00) heating is off. The antifreeze function stays on.
Sliding Temperature
When the optional external sensor is installed the generator adjustment system works with “Sliding Tem-
perature”. In this mode, the temperature of the heating system is controlled according to the outside
weather conditions, to ensure a high degree of comfort and energy-saving throughout the year. In particular,
as the outside temperature increases the system delivery temperature decreases according to a specific
“compensation curve“.
With the Sliding Temperature adjustment, the temperature set in parameter 1 of the operation menu be-
comes the maximum system delivery temperature. It is advisable to set a maximum value to permit system
adjustment throughout its useful working range.
The generator must be regulated at the time of installation by qualified personnel. Possible adjustments
can in any case be made by the user to improve comfort: in fact the compensation curve can be modified
from the operation menu with the
key and scrolling the menu with the
key to parameter 9.
The set compensation curve is displayed (see graph below). On pressing one of the
keys, the display
starts flashing and the required value can be set with the
keys. To activate the new curve, press
.
To cancel, do not press the
and press
.
If the room temperature is lower than the required value, it is advisable to set a higher curve and vice versa.
Proceed by increasing or decreasing in steps of one and check the result in the room.
Compensation curves