36
DOMIcompact F 30 D
4.7 Wiring diagram
Fig. 22
Key
16
Fan
32
Central heating pump
34
Heating temp. sensor
38
Flow
switch
42
Tap water temperature sensor
43
Air pressure switch
44
Gas valve
47
Modureg
49
Safety thermostat
72
Room
thermostat
81
Ignition/detection
electrode
114
Low water pressure switch
139
Remote timer control (opentherm)
34
43
49
MF08F
A.1
TRANSFORMER
42
11
4
44
16
32
230V 50Hz
X5
X3
X7
X2
X4
1 2
1
2
3
1
2
3
4
1234567
123456789
10
1
1
FUSE
FUSE
X1
N L
81
47
38
F 3.15A
F 3.15A
72
139
CAUTION
Before connecting the room thermostat or the
remote timer control, remove the jumper on the
terminal block. Use voltage free contacts only.
Summary of Contents for DOMIcompact F 30 D