Restoring Factory Values
See ”* Restore Factory Values” on page 332
.
0
P30
Heating ramp
10÷80
(ex. 10=20°C/min, 20=12°C/min, 40=6°C/min,
80=3°C/min)
40
P31
Heating standby time
0-10 minutes
4
P32
Heating Post-Circulation
0-255 minutes
15
P33
Pump operation
0
= Continuous pump (active only in winter mode)
1
= Modulating pump
1
P34
Pump modulation DeltaT
0 ÷ 40°C
20
P35
Modulating pump min. speed
30 ÷ 100%
30
P36
Modulating pump start speed
90 ÷ 100%
90
P37
Modulating pump max. speed
90 ÷ 100%
100
P38
Pump deactivation temperature
during Post-Circulation
0 ÷ 100°C
55
P39
Pump activation hysteresis tem-
perature during Post-Circulation
0 ÷ 100°C
25
P40
Heating user max. setpoint
20 ÷ 90°C
80
P41
Max. output in heating
0 ÷ 100%
BlueHelix HiTech RRT 24 C =
80
BlueHelix HiTech RRT 28 C =
85
BlueHelix HiTech RRT 34 C =
90
P42
Burner shutdown in DHW
0
= Fixed
1
= Linked to setpoint
2
= Solar
0
P43
Comfort mode activation tempe-
rature
0 ÷ 80°C
40
P44
Comfort mode deactivation hys-
teresis
0 ÷ 20°C
20
P45
DHW standby time
30 ÷ 255 seconds
120
P46
DHW user max. setpoint
40 ÷ 65°C
55
P47
DHW pump Post-Circulation
0 ÷ 255 seconds
30
P48
Max. output in DHW
0 ÷ 100%
100
P49
Not implemented (b01=2)
--
--
P50
Not implemented (b01=2)
--
--
P51
Solar off temperature
0 ÷ 100°C
10
P52
Solar on temperature
0 ÷ 100°C
10
P53
Solar standby time
0 ÷ 255 seconds
10
P54
System pre-circulation time
0 ÷ 60 seconds
30
P55
System filling mode
0
= Disabled
1
= Automatic
0
P56
Minimum system pressure limit
value
0-8 bar/10 (Only for boilers with water pressure sen-
sor)
4
P57
System nominal pressure value
5-20 bar/10 (Only for boilers with water pressure
sensor)
7
P58
Maximum system pressure limit
value
25-35 bar/10 (Only for boilers with water pressure
sensor)
28
P59
Not implemented
--
--
P60
Frost protection power
0 ÷ 50% (0 = minimum)
0
P61
Minimum power
0 ÷ 50% (0 = minimum)
0
Index Description
Range
Default
Summary of Contents for BlueHelix HiTech RRT C
Page 45: ...BlueHelix HiTech RRT C 45 IT cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 104: ...BlueHelix HiTech RRT C 104 ES cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 163: ...BlueHelix HiTech RRT C 163 RO cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 221: ...BlueHelix HiTech RRT C 221 PL cod 3541V300 Rev 00 02 2021 wygląd 48 wygląd 49 wygląd 50 5 6 6 ...
Page 280: ...BlueHelix HiTech RRT C 280 EL cod 3541V300 Rev 00 02 2021 İȚț 48 İȚț 49 İȚț 50 5 6 6 ...
Page 339: ...BlueHelix HiTech RRT C 339 EN cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 354: ......
Page 355: ......