BlueHelix HiTech RRT C
319
EN
cod. 3541V300 - Rev. 00 - 02/2021
Accessing the electrical terminal block and fuse
Remove the front panel ( ”Opening the front panel” on page 334 ) to access the terminal block (
M
)
and fuse (
F
) by proceeding as follows (fig. 28 and fig. 29).
The terminals indicated in fig. 28
must be with voltage-free contacts (not 230V)
. The arrangement of the terminals for the various
connections is also given in the wiring diagram in fig. 67.
fig. 28
fig. 29
Variable output relay card LC32 (optional - 043011X0)
The variable output relay
LC32
consists of a small card with a switchover of free contacts (closed
means contact between C and NO). Operation is managed by the software.
For installation, carefully follow the instructions provided in the kit package and on the wiring dia-
gram of fig. 67.
To use the desired function, refer to the table 3.
Table 3- Settings LC32
Parameter b07 Function LC32
Action LC32
0
Manages a secondary gas valve (default)
The contacts are closed when the gas valve (in
the boiler) is powered
1
Use as an alarm output (warning light comes
on)
The contacts are closed when there is an error
condition (generic)
M
5
6
72
139
1234
A
138
F
Summary of Contents for BlueHelix HiTech RRT C
Page 45: ...BlueHelix HiTech RRT C 45 IT cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 104: ...BlueHelix HiTech RRT C 104 ES cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 163: ...BlueHelix HiTech RRT C 163 RO cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 221: ...BlueHelix HiTech RRT C 221 PL cod 3541V300 Rev 00 02 2021 wygląd 48 wygląd 49 wygląd 50 5 6 6 ...
Page 280: ...BlueHelix HiTech RRT C 280 EL cod 3541V300 Rev 00 02 2021 İȚț 48 İȚț 49 İȚț 50 5 6 6 ...
Page 339: ...BlueHelix HiTech RRT C 339 EN cod 3541V300 Rev 00 02 2021 fig 48 fig 49 fig 50 5 6 6 ...
Page 354: ......
Page 355: ......