DUOX VEO XS AMBIANCE MONITOR
3
PROGRAMMING MENU
CONFIRM
PROGRAMMING
FROM THE MONITOR
3. MONITOR SETTINGS
ENTER NUMBER
MANUAL FULL
MONITOR
With an image on the monitor, by pressing the button
or the touch screen, (or upon receiving
a call without picking up), press the
key to show the video settings.
Select the settings
option and increase
or decrease.
VIDEO
SETTINGS
AUDIO
SETTINGS
While the audio channel is open, press the
button or the touch screen and a menu screen
appears for this setting.
Increase or decrease,
until obtaining the
desired regulation.
Notice: Maximum conversation time: 90 seconds.
MONITOR TECHNICAL CHARACTERISTICS
(TOUCH Screen 4.3”)
Power supply
18 Vdc
Standby consumption
77 mA
Maximum consumption 407 mA
Maximum consumption (with Inductive loop) 850 mA
Home automation consumption menu
140 mA
Operating temperature
[-5º , +40ºC] / [23º, 104ºF]
2
3
0 0 0 0 0 1
On the screen press
icon.
We access the screen to program the home number.
Enter the home number and confi rm with
when
fi nished.
Note: Once the monitor’s address has been programmed a
red led indicates it.
1
1
2
3
Contrast Brightness Colour