![Fermax STAND-ALONE CONTROLLER 1 DOOR WG Installer Manual Download Page 17](http://html1.mh-extra.com/html/fermax/stand-alone-controller-1-door-wg/stand-alone-controller-1-door-wg_installer-manual_553973017.webp)
Cod. 97864b V09_19
7
Set Access Mode
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi cards/PINs access
4 0 #
4 1 #
4 2 #
(Factory default)
4 3 (2~9) #
Example: 3 (3 cards valid or 3 PINS valid)
Example: 5 (5 cards valid or 5 PINS valid)
3. Exit Program Mode
*
Reset User’s
1.
*(Master code) #
2.
2
3.
(Master code) #
(Factory default is 123456)
Reset to Factory Default (
THE USER’S INFORMATION IS STILL RET
AINED)
1.
Power OFF.
2.
Connect GND and OPEN.
3.
Power ON.
4.
There will be two beeps, and the LED light turns into orange.
5.
Connect GND and OPEN or must press the Exit Button for at least 10 seconds before release.
User Information Transfer
User Information from Master controller to Slave controller is possible.
Connection Diagram: