START-UP ROUTINE
The MDS Digitiser has a start-up routine that allows the installer to verify if the modules connection has been
properly made, otherwise, if there is a problem with the connections, and the information on the incorporated
firmware version.
After powering it, the front display shows the firmware version and then indicates the type of modules detected and
their order, that is, the first information indicates what type of module is connected directly to the Digitiser, and the
following information indicates the next one's or module's type.
If no module is detected (due to a failure or if not connected), this routine will continue to repeat, until one is detected.
The digitiser's front indicators blink and the display only indicates the firmware version and the "Err" (error).
The type or types of modules detected will determine the panel's operating mode (MDS DIRECT, MDS CITY or
mixed). The following diagram schematically represents this start-up routine:
RESTORING DEFAULT SETTINGS
You can reset the Digitiser's configuration to its default values. This is useful, for example, if you don't know the
mode it's configured in and want to start from a known value.
The default configuration values are as follows:
- Panel number: 01
- Block number: 00
- Lock-release activation time (when opened from the residence): 3 seconds.
. Lock-release activation time (when opened from the entrance hall's button): 6 seconds
- Conversation time. Max.: 60 seconds. Min: 16 seconds
- NIGHT MODE Panel.
This operation can only be performed on panels with the keypad module, or those provisionally connected to one.
The steps for restoring are to power the system and enter "A-7-0-8-BELL-9" on the keypad in less than 1 minute's
time.
DESCRIPTION OF THE MDS DIGITISER REF. 7460
Before 1 minute
Button module/s detected
This is repeated as long as no module is detected
(keypad and/or buttons) connected to the Digitiser
The indicators blink
Keypad detected
B keypad module/s detected
No buttons or keypads detected
Version of the
Digititiser (1.0)
button module/s detected
ON
708 9
A
OK
OK
OK
OK
ON
Summary of Contents for SKYLINE MDS 7460
Page 2: ......
Page 20: ......
Page 26: ......
Page 50: ......
Page 52: ...L L L VIDEO DISTRIBUTION 2BRANCHDISTRIBUTION 18 4 3 V M V M V M V M REF 2448 COAX COAX COAX...