3:
basic settings - resets all values to factory settings except for the memory of
numbers
4:
sets the starting IP address to 192.168.1.250
All changes show always after turning off and turning on of the power supply
(restart).
The DIP switch 3 and 4 needs to be switched back to "on" position after the start
of VoIP module. Otherwise after the restart the set parameters or the new IP
address are rewritten back to the default mode.
15. Output of 12VDC (max. 350mA!). This output is used primarily for supplying the
power to the lowconsumption electrical lock when PoE is used.
16. Switching contact 2 (NO= normally open, NC= normally closed and COM=
common output of the switch).
17. Connector 8 - for connecting 8 pushbuttons
(integrated expansion). For connection
please use an interconnection cable Fermax
PBX CC8. Each colour of the cable is
assigned exactly for a specific pushbutton -
see picture 3.
Connection of pushbuttons:
black = 3rd pushbutton
orange = 4th pushbutton
green = 5th pushbutton
white
= 6th pushbutton
red
= 7th pushbutton
yellow = 8th pushbutton
brown = 9th pushbutton
blue
= 10th pushbutton
The numbers of pushbuttons begin with 3, because the first two buttons are
integrated on the basic panel.
18. Connector 5 - connection of the 8-pushbutton expansion Fermax PBX EXP or the
keypad Fermax PBX KEY. The connection is done via Fermax PBX CC5 cable. It is a
data connection only. Power supply of illumination and the common output is on
the Connector 3.
19. Connector 3 - it is used for connection of the power supply and the common
output of the pushbuttons. The original Fermax cable is used (Fermax PBX CC3).
Picture 3 Cable Fermax PBX CC8
13
Summary of Contents for PBX EA
Page 17: ...Picture 5 Connection of expansion modules 17 ...
Page 38: ...3 1 11 Restart ...
Page 42: ......