Page 25
LYNX Monitor
Type.
Area type:
* 24/7 Area. 24 hours, 7 days. Sensors such as smoke, gas, water, etc. which are always armed.
* Night Area. Perimeter-control and movement sensors.
* Out Area. All types of sensors.
Mode.
Area Working Mode: NO (Normally open) / NC (normally closed). The fi rst eight areas will
be NC (normally closed), the other 8 areas can be confi gured to NC or NO as desired (starting
from zone 9).
I/O.
Area Activation Mode: I (immediate) / D (delayed).
The alarm system can be confi gured in 3 ways:
-
Home:
Only 24/7 areas are armed.
-
Sleep
: 24/7 areas and Night areas are armed.
- Out:
All areas are armed.
To confi gure the various parameters, simply press them and the available options will be displayed.
3.1.9.6 General Settings. Installer Settings
Home
Automation SETTINGS
The
Home
Automation Settings
function allows you to confi gure the various web servers that
are included in the automation controllers available to the home.
The monitor’s
automation
function can manage an automation system transparently, i.e. the
monitor screen displays the information provided by an external automation centre via a web
browser.
Up to 5 different servers can be pre-confi gured (by the installer). If more than 1 is confi gured,
the automation icon provides a list (of labels), so that the user can select the one they desire.
For further details see chapter
3.2.6 Automation.