ADS Bus:
L
: Audio and data bus.
+, -
: 18 Vdc power supply.
•
Video:
CH1+
: ADS channel 1 video input (connection of live).
CH1-
: Earth of ADS channel 1 video (connection of the shield).
CH2+
: Channel 2 auxiliary video input (connection of live).
CH2-
: Earth of channel 2 auxiliary video (connection of the shield).
•
Inputs/outputs (configurable by means of the ADS IP application):
DI+
: Positive digital input.
DI-
: Reference digital input
DO, DO
: Dry contact of relay.
•
Ethernet network/Internet connection:
LAN
: Connection to ethernet network/Internet (RJ45
).
Interface Connectors
•
Restore Default:
Returns to factory values (configuration of network, ADS number, users...).
(Press and hold the button for about 5 seconds).
•
Reset:
Restarts the equipment.
Leds
POWER
Equipment powered
Equipment not powered
LAN
Network connection available
Network connection unavailable
PRG
Accepts programming of ADS address
Standby
CH
ADS video channel 1 active
Auxiliary video channel 2 active
ON
OFF
DO
LAN
DI
- +
CH2
CH1
PWR
- +
- +
- + L
Restore Default
Configuración
Fábrica
Reset
POWER
LAN
PRG
CH
INTERFAZ IP ADS
ADS IP INTERFACE
REF. 1304
INPUT
18V 500 mA