Installation & Operating Instructions
A
DJUSTING THE
V
OLTAGE
/ F
REQUENCY
(V/
F
)
CHARACTERISTICS
The V/f characteristic is defined by several parameters as shown. Reducing the
voltage at a particular frequency reduces the current in the motor and hence the
torque and power. The V/f curve can be further modified by using P-28 and P-29,
where P-28 determines the percentage increase or decrease of the voltage applied
to the motor at the frequency specified in P-29. This can be useful if motor
instability is experienced at certain frequencies, if this is the case increase or
decrease the voltage (P-28) at the speed of instability (P-29).
For applications requiring energy saving, typically HVAC and pumping, the energy
optimiser (P-06) parameter can be enabled. This automatically reduces the applied
motor voltage on light load.
P-00 R
EAD
O
NLY
D
RIVE
S
TATUS
P
ARAMETERS
7.2.1. P
ARAMETER GROUP ZERO ACCESS AND NAVIGATION
When P-14 = P-37, all P-00 parameters are visible. Default value is 101.
When the user scrolls to P-00, pressing will display
“
P00-HH
”
, where HH represents the secondary number within P-00.
(i.e. 1 to 20). The User can then scroll to the required P-00 parameter.
Pressing once more will then display the value of that particular group zero parameter.
For those parameters which have multiple values (e.g. software ID), pressing the and keys will display the different
values within that parameter.
Pressing returns to the next level up. If is then pressed again (without pressing or ), the display changes to the
next level up (main parameter level, i.e. P-00).
If or is pressed whilst on the lower level (e.g. P00-05) to change the P-00 index, pressing <NAVIGATE> quickly displays
that parameter value.
8. A
NALOG AND
D
IGITAL
I
NPUT
C
ONFIGURATIONS
8.1. T
ERMINAL MODE
(P-12 =0)
Negative Preset Speeds will be inverted if Run Reverse selected.
NOTE
T
YPICAL
A
PPLICATIONS
Analog speed input with 1 preset speed
and fwd/rev switch
Analog speed input with 2 preset speeds
4 preset speeds and max speed select
switch. Effectively giving 5 preset speeds
Description
Display range
Explanation
P00-01
1st Analog input value
0 … 100%
100% = max input voltage
P00-02
2nd Analog input value
0 … 100%
100% = max input voltage
P00-03
Speed reference input
-P1-01 … P1-01
Displayed in Hz if P-10 = 0, otherwise displayed in RPM
P00-04
Digital input status
Binary value
Drive digital input status
P00-05
Reserved
0
Reserved
P00-06
Reserved
0
Reserved
P00-07
Applied motor voltage
0 … 600V AC
Value of RMS voltage applied to motor
P00-08
DC bus voltage
0 … 1000V dc
Internal DC bus voltage
P00-09
Internal Heatsink temperature
-20 … 100 °C
Temperature of heatsink in °C
P00-10
Hours run meter
0 to 99 999 hours
Not affected by resetting factory default parameters
Run-time clock stopped by drive disable (or trip), reset on next
P00-11
Run time since last trip (1)
0 to 99 999 hours
enable only if a trip occurred. Reset also on next enable after a drive
power down.
Run-time clock stopped by drive disable (or trip), reset on next
P00-12
Run time since last trip (2)
0 to 99 999 hours
enable only if a trip occurred (under-volts not considered a trip) –
not reset by power down / power up cycling unless a trip occurred
prior to power down
P00-13
Run time since last disable
0 to 99 999 hours
Run-time clock stopped on drive disable, value reset on next enable
Actual drive effective output switching frequency. This value maybe
P00-14
Drive Effective Switching
4 to 32 kHz
lower than the selected frequency in P-17 if the drive is too hot.
Frequency
The drive will automatically reduce the switching frequency to
prevent an over temperature trip and maintain operation.
P00-15
DC bus voltage log
0 … 1000V
8 most recent values prior to trip, updated every 250ms
P00-16
Thermistor temperature log
-20 … 120 °C
8 most recent values prior to trip, updated every 500ms
P00-17
Motor current
0 to 2x rated current
8 most recent values prior to trip, updated every 250ms
Version number and checksum.
P00-18
Software ID, IO & motor ctrl
e.g. “1.00”, “47AE”
“1” on LH side indicates I/O processor,
“2“ indicates motor control
P00-19
Drive serial number
000000 … 999999
Unique drive serial number
00-000 … 99-999
e.g. 540102 / 32 / 005
P00-20
Drive identifier
Drive rating
Drive rating, drive type
e.g. 0.37, 1 230,3P-out
P-15
Digital input 1 (T2)
Digital input 2 (T3)
Digital input 3 (T4)
Analog input (T6)
Comments
0
Open: Stop (disable)
Open : Forward run
Open : Analog speed ref
Analog input 1 reference
Closed: Run (enable)
Closed : Reverse run
Closed : Preset speed 1
1
Open: Stop (disable)
Open: Analog speed ref
Open: Preset speed 1
Analog input 1 reference
Closed: Run (enable)
Closed:Preset speed 1/2
Closed:Preset speed 2
Open: Stop (disable)
Digital Input 2
Digital Input 3
Preset Speed
4 Preset speeds
Closed: Run (enable)
Open
Open
Preset Speed 1
Open: Preset speeds 1-4
selectable.
2
Closed
Open
Preset Speed 2
Closed:Max Speed(P-01)
Analog input used as
Open
Closed
Preset Speed 3
digital input Closed status:
Closed
Closed
Preset Speed 4
8V < Vin < 30V
Open: Stop (disable)
Open : Analog speed ref
External trip input :
Connect external
3
1)
Closed: Run (enable)
Closed : Preset speed 1
Open: Trip,
Analog input 1 reference thermistor type PT100 or
Closed: Run
similar to digital input 3
4
Open: Stop (disable)
Open : Analog input 1
Analog input 2 reference
Analog input 1 reference
Switches between analog
Closed: Run (enable)
Closed : Analog input 2
inputs 1 and 2
Open: Fwd Stop
Open: Reverse Stop
Open : Analog speed ref
Closing digital inputs 1
5
Closed: Fwd Run
Closed: Reverse Run
Closed : Preset speed 1
Analog input 1 reference and 2 together carries out
a fast stop (P-24)
Open: Stop (disable)
Open : Forward
External trip input :
Connect external
6
1)
Closed: Run (enable)
Closed : Reverse
Open: Trip,
Analog input 1 reference thermistor type PT100 or
Closed: Run
similar to digital input 3
Open: Stop (disable)
Open: Stop (disable)
External trip input :
Closing digital inputs 1
7
Closed: Fwd Run (enable) Closed: Rev Run (enable)
Open: Trip,
Analog input 1 reference and 2 together carries
Closed: Run
out a fast stop (P-24)
Digital Input 3
Analog Input 1
Preset Speed
Open: Stop (disable)
Open : Forward
Open
Open
Preset Speed 1
8
Closed: Run (enable)
Closed : Reverse
Closed
Open
Preset Speed 2
Open
Closed
Preset Speed 3
Closed
Closed
Preset Speed 4
Digital Input 3
Analog Input 1
Preset Speed
Open: Stop (disable)
Open: Stop (disable)
Open
Open
Preset Speed 1
Closing digital inputs 1
9
Closed: Forward Run
Closed: Reverse Run
Closed
Open
Preset Speed 2
and 2 together carries out
(enable)
(enable)
Open
Closed
Preset Speed 3
a fast stop (P-24)
Closed
Closed
Preset Speed 4
10
Normally Open (NO)
Normally Closed (NC)
Open : Analog speed ref
Analog input 1 reference
Momentary close to run
Momentary open to stop
Closed:Preset speed 1
Normally Open (NO)
Normally Closed (NC)
Normally Open (NO)
Closing digital inputs 1
11
Momentary close to run
Momentary open to stop
Momentary close to rev
Analog input 1 reference and 3 together carries out
a fast stop (P-24)
12
Open: Stop (disable)
Open: Fast Stop (disable)
Open : Analog speed ref
Analog input 1 reference
Closed: Run (enable)
Closed: Run (enable)
Closed : Preset speed 1
Fenner QDE User Guide 9/5/08 9:23 AM Page 15