Installation & Operating Instructions

A

DJUSTING THE

V

OLTAGE

/ F

REQUENCY

(V/

F

CHARACTERISTICS

The V/f characteristic is defined by several parameters as shown. Reducing the
voltage at a particular frequency reduces the current in the motor and hence the
torque and power. The V/f curve can be further modified by using P-28 and P-29,
where P-28 determines the percentage increase or decrease of the voltage applied
to the motor at the frequency specified in P-29. This can be useful if motor
instability is experienced at certain frequencies, if this is the case increase or
decrease the voltage (P-28) at the speed of instability (P-29).

For applications requiring energy saving, typically HVAC and pumping, the energy
optimiser (P-06) parameter can be enabled.  This automatically reduces the applied
motor voltage on light load.

P-00 R

EAD

O

NLY

D

RIVE

S

TATUS

P

ARAMETERS

7.2.1. P

ARAMETER GROUP ZERO ACCESS AND NAVIGATION

When P-14 = P-37, all P-00 parameters are visible.  Default value is 101.

When the user scrolls to P-00, pressing         will display 

P00-HH

, where HH represents the secondary number within P-00.

(i.e. 1 to 20).  The User can then scroll to the required P-00 parameter.

Pressing        once more will then display the value of that particular group zero parameter.

For those parameters which have multiple values (e.g. software ID), pressing the      and       keys will display the different
values within that parameter.

Pressing        returns to the next level up.  If        is then pressed again (without pressing      or     ), the display changes to the
next level up (main parameter level, i.e. P-00).

If      or      is pressed whilst on the lower level (e.g. P00-05) to change the P-00 index, pressing <NAVIGATE> quickly displays
that parameter value.

8. A

NALOG AND

D

IGITAL

I

NPUT

C

ONFIGURATIONS

8.1. T

ERMINAL MODE

(P-12 =0)

Negative Preset Speeds will be inverted if Run Reverse selected.

NOTE

T

YPICAL

A

PPLICATIONS

Analog speed input with 1 preset speed

and fwd/rev switch

Analog speed input with 2 preset speeds

4 preset speeds and max speed select

switch.  Effectively giving 5 preset speeds

Description

Display range

Explanation

P00-01

1st Analog input value

0 … 100%

100% = max input voltage

P00-02

2nd Analog input value

0 … 100%

100% = max input voltage

P00-03

Speed reference input

-P1-01 … P1-01

Displayed in Hz if P-10 = 0, otherwise displayed in RPM

P00-04

Digital input status

Binary value

Drive digital input status

P00-05

Reserved

0

Reserved

P00-06

Reserved

0

Reserved

P00-07

Applied motor voltage

0 … 600V AC

Value of RMS voltage applied to motor

P00-08

DC bus voltage

0 … 1000V dc

Internal DC bus voltage

P00-09

Internal Heatsink temperature

-20 … 100 °C

Temperature of heatsink in °C

P00-10

Hours run meter

0 to 99 999 hours

Not affected by resetting factory default parameters

Run-time clock stopped by drive disable (or trip), reset on next 

P00-11

Run time since last trip (1)

0 to 99 999 hours

enable only if a trip occurred.  Reset also on next enable after a drive
power down.

Run-time clock stopped by drive disable (or trip), reset on next 

P00-12

Run time since last trip (2)

0 to 99 999 hours

enable only if a trip occurred (under-volts not considered a trip)  –  
not reset by power down / power up cycling unless a trip occurred 
prior to power down

P00-13

Run time since last disable

0 to 99 999 hours

Run-time clock stopped on drive disable, value reset on next enable

Actual drive effective output switching frequency.  This value maybe 

P00-14

Drive Effective Switching 

4 to 32 kHz

lower than the selected frequency in P-17 if the drive is too hot.  

Frequency

The drive will automatically reduce the switching frequency to 
prevent an over temperature trip and maintain operation.

P00-15

DC bus voltage log

0 … 1000V

8 most recent values prior to trip, updated every 250ms

P00-16

Thermistor temperature log

-20 … 120 °C

8 most recent values prior to trip, updated every 500ms

P00-17

Motor current

0 to 2x rated current

8 most recent values prior to trip, updated every 250ms

Version number and checksum.  

P00-18

Software ID, IO & motor ctrl

e.g.  “1.00”,  “47AE”

“1” on LH side indicates I/O processor,  

“2“ indicates motor control

P00-19

Drive serial number

000000 … 999999

Unique drive serial number 

00-000 … 99-999

e.g.   540102 / 32 / 005

P00-20

Drive identifier

Drive rating 

Drive rating, drive type 

e.g. 0.37, 1 230,3P-out

P-15

Digital input 1 (T2)

Digital input 2 (T3)

Digital input 3 (T4)

Analog input (T6)

Comments

0

Open: Stop (disable)

Open : Forward run

Open : Analog speed ref

Analog input  1 reference

Closed: Run (enable)

Closed : Reverse run

Closed : Preset speed 1

1

Open: Stop (disable)

Open: Analog speed ref

Open: Preset speed 1

Analog input  1 reference

Closed: Run (enable)

Closed:Preset speed 1/2

Closed:Preset speed 2

Open: Stop (disable)

Digital Input 2

Digital Input 3

Preset Speed

4 Preset speeds 

Closed: Run (enable)

Open

Open

Preset Speed 1

Open: Preset speeds 1-4

selectable. 

2

Closed

Open

Preset Speed 2

Closed:Max Speed(P-01)

Analog input used as

Open

Closed

Preset Speed 3

digital input Closed status:

Closed

Closed

Preset Speed 4

8V < Vin < 30V  

Open: Stop (disable)

Open : Analog speed ref

External trip input :

Connect external 

1)

Closed: Run (enable)

Closed : Preset speed 1

Open: Trip, 

Analog input  1 reference thermistor type PT100 or 

Closed: Run

similar to  digital input 3

4

Open: Stop (disable)

Open : Analog input 1

Analog input 2 reference

Analog input  1 reference

Switches between analog

Closed: Run (enable)

Closed : Analog input 2

inputs 1 and 2

Open: Fwd Stop

Open: Reverse Stop

Open : Analog speed ref

Closing digital inputs 1

5

Closed: Fwd Run

Closed: Reverse Run

Closed : Preset speed 1

Analog input  1 reference and 2  together carries out

a fast stop (P-24)

Open: Stop (disable)

Open : Forward 

External trip input :

Connect external 

1)

Closed: Run (enable)

Closed : Reverse

Open: Trip, 

Analog input  1 reference thermistor type PT100 or

Closed: Run

similar to  digital input 3

Open: Stop (disable)

Open: Stop (disable)

External trip input :

Closing digital inputs 1

7

Closed: Fwd Run (enable) Closed: Rev Run (enable)

Open: Trip, 

Analog input  1 reference and 2  together carries 

Closed: Run

out a fast stop (P-24)

Digital Input 3

Analog Input 1

Preset Speed

Open: Stop (disable)

Open : Forward

Open

Open

Preset Speed 1

Closed: Run (enable)

Closed : Reverse

Closed

Open

Preset Speed 2

Open

Closed

Preset Speed 3

Closed

Closed

Preset Speed 4

Digital Input 3

Analog Input 1

Preset Speed

Open: Stop (disable)

Open: Stop (disable)

Open

Open

Preset Speed 1

Closing digital inputs 1

9

Closed: Forward Run 

Closed: Reverse Run

Closed

Open

Preset Speed 2

and 2  together carries out

(enable)

(enable)

Open

Closed

Preset Speed 3

a fast stop (P-24) 

Closed

Closed

Preset Speed 4

10

Normally Open (NO)

Normally  Closed (NC)

Open : Analog speed ref

Analog input  1 reference

Momentary close to run

Momentary open to stop

Closed:Preset speed 1

Normally Open (NO)

Normally  Closed (NC)

Normally Open (NO)

Closing digital inputs 1

11

Momentary close to run

Momentary open to stop

Momentary close to rev

Analog input  1 reference and 3  together carries out

a fast stop (P-24)

12

Open: Stop (disable)

Open: Fast Stop (disable)

Open : Analog speed ref

Analog input  1 reference

Closed: Run (enable)

Closed: Run (enable)

Closed : Preset speed 1

Fenner QDE User Guide  9/5/08  9:23 AM  Page 15

Summary of Contents for QD:E 572B20P4

Page 1: ...Installation and Operating Instructions Fenner QDE User Guide 9 5 08 9 23 AM Page 1 ...

Page 2: ...nner QD E Easy Start Up Guide 20 Declaration of Conformity ERIKS Industrial Services Ltd hereby states that the Fenner QD E Series product range is CE marked for the low voltage directive and conforms to the following harmonised European directives EN 61800 5 1 2003 Adjustable speed electrical power drive systems Safety requirements Electrical thermal and energy EN 61800 3 2nd Adjustable speed ele...

Page 3: ...Use Only Flammable material should not be placed close to the drive The entry of conductive or flammable foreign bodies should be prevented Relative humidity must be less than 95 non condensing Ensure that the supply voltage frequency and no of phases 1 or 3 phase correspond to the rating of the Fenner drive as delivered An isolator should be installed between the power supply and the drive Never ...

Page 4: ...evels Failure to observe this precaution could result in severe bodily injury or loss of life Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applicable manuals in their entirety before proceeding Failure to observe this preca...

Page 5: ...al voltage is normally selected when installing the motor by selecting either STAR or DELTA connection STAR always gives the higher of the two voltage ratings Typical ratings are 5 1 CONTROL TERMINAL CONNECTIONS 5 2 RJ45 DATA CONNECTION 6 OPERATION 6 1 MANAGING THE KEYPAD The drive is configured and its operation monitored via the keypad and display Control Signal Description Terminal 1 24V User O...

Page 6: ...l show the target speed use the keys to adjust as required then press the key to return the display to STOP 10 Pressing the key will start the drive accelerating to the target speed To allow the Fenner drive to be controlled from the keypad in a forward and reverse direction set P 12 2 11 Operation is the same as when P 12 1 for start stop and changing speed 12 Press the key The display changes to...

Page 7: ...g a trip for the drive to run Auto 0 drive will run whenever digital input 1 is closed if not tripped Terminal mode Auto 1 5 drive will make 1 5 attempts to P 30 restart function EdgE r Auto 0 Auto 5 Auto 0 automatically restart after a trip 25s between attempts If fault has cleared drive will restart To reset the counter the Drive must be powered down reset on the keypad or by re enabling the dri...

Page 8: ...y power down power up cycling unless a trip occurred prior to power down P00 13 Run time since last disable 0 to 99 999 hours Run time clock stopped on drive disable value reset on next enable Actual drive effective output switching frequency This value maybe P00 14 Drive Effective Switching 4 to 32 kHz lower than the selected frequency in P 17 if the drive is too hot Frequency The drive will auto...

Page 9: ...n Stop disable Closed remote UP Closed remote DOWN Open Forward 5 Closed Run enable push button push button 24V Reverse 8 12 2 Open Stop disable Closed remote UP Closed remote DOWN Open Keypad speed ref Closed Run enable push button push button 24V Preset speed 1 Open Stop disable Closed remote UP External trip input Closed remote DOWN Connect external 3 1 Closed Run enable push button Open Trip C...

Page 10: ...W 5HP 240V rms AC 5kA rms AC 400 460V ratings 0 75kW 1HP to 7 5kW 10HP 480V rms AC 5kA rms AC P 15 Digital input 1 T2 Digital input 2 T3 P dEF Factory Default parameters Press STOP key drive is ready to configure for particular application have been loaded Motor at constant speed investigate overload or malfunction Over current on drive output Motor starting load stalled or jammed Check for star d...

Page 11: ...ııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııııı Page 20 www fptgroup com Fenner is a registered trademark of J H Fenner Co Limited Installation Operating Instructions Fenner QD E Fenner QDE User Guide 9 5 08 9 24 AM Page 21 ...