Troubleshooting

If the following problems occur, please perform checks and fix.

Problem

Check 

Action

No air blows 
even if hands 
are inserted

The unit does 
not stop blowing

No hot air 
comes out
 

Indicator light 
is flashing

Heater is built-in, 
is the heater sensor 
dirty?

If the power supply 
problems occur,the 
indicator  lights  up 
and is flashing.

Do the display 
indicators lights up?
Is the power switch 
on?
Are you putting your 
hands all the way in?

Is the sensor blocked 
by the dirt or dust?

Turn the ground-fault circuit breaker on.

Turn the power switch on.

Put hands all the way in.

Turn the power switch off, and then, 
after all the lamps in the display have 
gone off,  remove

 

the dust matter. 

Then turn on the power swtich.

Is the room temperature over 20 ЎЈ
Turn the power switch off. Remove 
the  front

 

panel,  then  remove  the 

cover

 

of

 

terminal

 

box,

  

check

 

the 

fuse (terminal connector)

  

whether 

burnt or not.

Turn the power switch off. Check all 
the  indicators  in  the  display  area  
have gone off  (around  40 seconds), 
then turn on the power switch again.

No power

Turn off power, take down the machine 
and

 

ask

 

the

 

technician

 

to

 

replace  the 

power cable.

If  the  above  actions  do  not  work, turn off the power and the ground-fault circuit 
breaker, and call your dealer to inspect and repair it if necessary. (Costs are as per 
agreement with the dealer)

Wiring Diagram

9

T

emperature sensor

Power supply

Balanced inductor

Display board

Panel control board

Electrical wiring diagram

Emitter board

Lighting and 

receptor board

Microcomputer master control board

PTC heater

Inductor

Magnetic ring

Motor

Check the malfunction 

 light    

go 

out   

blinking

Fault LED    Check items           Causes and treatment

Power / abnormal  voltage 

Check the power connection and  confirm the voltage normal.

T

amper-proof timer

Sensor fault, continuous operation,  check whether or not the sensor is  blocked.

Summary of Contents for 300

Page 1: ...Usage and Installation Manual Dual Jet High Speed Hand Dryer N831 R00 23 03 20...

Page 2: ...y environmentfriendlyanddurability Two airstreamsof highspeed injection dry water drip off your hands within 7 seconds and give you convenience and comfort Thisunitisapplicabletothehomes restaurants b...

Page 3: ...in the bathtub or shower room Do not allow the unit get wet Prohibit disassembling Important Always follow instructions closely Earth grounding connection WARNING If you don t use this unit properly...

Page 4: ...supply Air Speed switch Press the Air Speed switch high speed and low speed switches are changeable Power indicator lamp is red when the high speed switch is turned on while the power lamp is green w...

Page 5: ...unit Note Draining and Cleaning the drain tank Before it fills up at least once a week The water blown off the hands is called drain water Empty the drain water at any moment in order to prevent accum...

Page 6: ...e top panel Push it all the way inward until it stops Dirt and dust may get into the unit and shorten its working life if the air filter is out of position Re attach to the unit As the original Align...

Page 7: ...cover of terminal box check the fuse terminal connector whether burnt or not Turn the power switch off Check all the indicators in the display area have gone off around 40 seconds then turn on the pow...

Page 8: ...lot of condensation Locations where corrosive neutral or reductive gases are present Installation position guide Leave at least 400mm clearance at both sides to make it easier to use Install the unit...

Page 9: ...g screws as shown the below figure Rear backinstallation panel Anti theft screw Installation panel Power connection Use a single phase 220 240V power 2 2 A single wire cable core between 2 0mm and 2 5...

Page 10: ...tors go off after 40 seconds Confirm ON 1 230mm 200mm 2 Power connection The second method of power connection cut off plug Embed the switch box with no cover in the installation position used to conn...

Reviews: