Fema LP4 User Manual Download Page 7

 Model LP4

SERIES SPECIAL . LOOP POWERED METERS

www.fema.es 

7

13 Configuration menu (cont.)

  the  ‘

Memory  of  maximum

’  (

MAX

)  displays  the maximum  reading 

stored on memory. To reset this memory, select the ‘

rSt

’ input. The 

value can be accessed through the ‘

fast access

’ menu at front key ‘

UP

’ 

(

5

) (see section 13.4).

  the  ‘

Memory  of  minimum

’  (

MIn

)  displays  the  minimum  reading 

stored on memory. To reset this memory, select the ‘

rSt

’ input. The 

value can be accessed through the ‘fast access’ menu at front key ‘

UP

’ 

(

5

) (see section 13.4).

Key ‘UP’  

(fast access)

Memory of max.

Memory of min.

Measure function

Tools

Input range

Version

Input low

Input high

Password

Factory reset

13.4 Key UP (fast access)

The  key  ‘

UP

’  (

5

)  at  the  front  of  the  instrument  gives  access  to  a 

configurable list of functions. See section 12 for information on how to 

operate the ‘

fast access

’ menu.

At the ‘

Key UP

 (

fast access

)’ (

K.uP

) menu select which functions will be 

available when pressing the front key ‘

UP

’ (

5

). Select ‘

on

’ to activate the 

desired functions.

 Select ‘

Memory of max

.’ (

MAX

) to activate access to the memory of 

maximum value, and reset function.

 Select ‘

Memory of min

.’ (

MIn

) to activate access to the memory of 

minimum value, and reset function.

 Select ‘

Measure function

’ (

MEAS

) to activate an access to visualize 

the actual input signal value, in milliamperes, without the scaling.

13.5 ‘Tools’ menu

The ‘

Tools’

 (

tool

) menu groups several functions.

 at the ‘

Input range

’ (

InP.r

) menu entry, manually configure the ‘

input 

low

’ and the ‘

input high

’ values. These values are by default set to ‘

4.00

’ 

and ‘

20.00

’ milliamperes, and are associated to the ‘

display low

’ and 

display high

’ parameters. See section for a detail on the 2 points 

associated to scaling.

  at  ‘

Brightness

’  (

LIGh

)  select  ‘

uniform

’  for  a  constant  brightness, 

independent  of  the  input  signal.  Select  ‘

adaptive

’  to  get  higher 

brightness when input signal is higher than 6 mA (aprox.).

  the  ‘

Version

’  (

VEr

)  parameter  informs  about  the  firmware  version 

running in the instrument.

 at the ‘

Password

’ (

PASS

) parameter define a 4 digit code to block 

access to the ‘

configuration menu

’. Activate the password to prevent 

access to the instrument configuration by non authorized personnel. 

To activate the ‘

Password

’ function, enter the code and validate. The 

password will be requested when entering the ‘

configuration menu

’. 

The password does not block access to the ‘

fast access

’ menu. To 

deactivate the password, set the password value to ‘0000’.

  at  the  ‘

Factory  reset

’  (

FAct

)  parameter  select  ‘

yes

’  to  activate  the 

default  factory  configuration  (see  section  19  for  a  list  of  factory 

default parameters).

Brightness

Adaptive

Uniform

Summary of Contents for LP4

Page 1: ...www fema es SPECIAL YOUR METER APPLICATIONS Model LP4 USER S MANUAL Loop mA LOOP POWERED PROCESS METER SERIES SPECIAL 5137r01...

Page 2: ...6 13 4Key UP fast access 7 13 5 Tools menu 7 14 Technical specifications 8 15 Error codes 8 16 Mechanical dimensions mm inch 8 17 Precautions on installation 9 18 Warranty 9 19 Factory default paramet...

Page 3: ...d connections Inverted connections will not damage the instrument the loop will remain open and the instrument does not operate display does not light Terminal 2 is not connected Connecting any of the...

Page 4: ...ries parameters and select configuration values Key SQ functions as the ENTER key It selects the menu entry currently displayed At numerical value entries it validates the number displayed Key UP 5 mo...

Page 5: ...r appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates When exiting the fast access menu the instrument returns to normal mode of operation...

Page 6: ...ads wait while performs the reading of the actual input signal value and associates this value to the input low parameter When finished the instrument goes back to the Correction low F Lo menu entry a...

Page 7: ...ect Measure function MEAS to activate an access to visualize the actual input signal value in milliamperes without the scaling 13 5 Tools menu The Tools tool menu groups several functions at the Input...

Page 8: ...isplay display refresh 2 times second acquisition per second 2 acquisitions second memory retention values for maximum and minimum reading are stored every 10 minutes INPUT SIGNAL signals accepted 4 2...

Page 9: ...r than the minimum current needed The instrument is designed to be panel mounted An appropriate ventilation of the instrument must be assured Do not expose the instrument to excess of humidity Maintai...

Page 10: ...of LP4 loop powered meter placed close to the transmitter using the existing loop to the PLC 4 20mA transmitter Units LP4 loop powered meter PLC The LP4 loop powered meter can be directly inserted int...

Page 11: ...2 3Protector KIP Wall mount housing Together with the KIP protector offers a full IP65 protection For for 96x48mm panel meters 22 2 4WME wall housing Benchtop housing for for 96x48mm panel meters Han...

Page 12: ......

Reviews: