![Fema LP4 User Manual Download Page 9](http://html1.mh-extra.com/html/fema/lp4/lp4_user-manual_3957750009.webp)
SERIES SPECIAL . LOOP POWERED METERS
9
17. Precautions on installation
This instrument is warranted against all manufacturing defects for a
period of 24 months, as requested by the European legislation. This
warranty does not apply in case of misuse or accident, and the scope
of the warranty is limited to repair of the instrument, not being the
manufacturer responsible for additional damages or additional costs.
Within the warranty period and after examination by the manufacturer,
the unit will be repaired or substituted when found to be defective.
Extended warranty available at (see section 4)
18. Warranty
Scaling
Decimal point
xxxx
Display low
0
Display high
9000
Display
Square root
off
Average filter
0
Steps
1
Left zeros
off
Memory of maximum
-1999
Memory of minimum
9999
Key ‘UP’ (fast access)
Memory of maximum
on
Memory of minimum
on
Measure function
on
Tools
Input range
Input low
4.00 [mA]
Input high
20.00 [mA]
Brightness
adaptive
Password
off (0000)
This instrument has been designed and verified conforming to the
61010-1 CE Security Regulation, for industrial applications. Installation
of this instrument must be performed by qualified personnel only. This
manual contains the appropriate information for the installation. Using
the instrument in ways not specified by the manufacturer may lead to a
reduction of the specified protection level. Disconnect the instrument
from all external circuits before starting any maintenance and / or
installation action.
The instrument does not have a general switch and will start operation as
soon as signal is connected and the current is higher than the minimum
current needed.
The instrument is designed to be panel mounted. An appropriate
ventilation of the instrument must be assured. Do not expose the
instrument to excess of humidity. Maintain clean by using a humid
rag and do NOT use abrasive products such as alcohols, solvents, etc.
General recommendations for electrical installations apply, and for
proper functionality we recommend: if possible, install the instrument far
from electrical noise or magnetic field generators such as power relays,
electrical motors, speed variators, ... If possible, do not install along the
same conduits power cables (power, motor controllers, electrovalves, ...)
together with signal and/or control cables. In case of fire, disconnect
the instrument from the power line, fire alarm according to local rules,
disconnect the air conditioning, attack fire with carbonic snow, never
with water.
Instrument conforms to CE rules and regulations.
19. Factory default parameters
Manufacturer
FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - [email protected]
Products
LP4
The manufacturer declares that the instruments indicated comply with the
directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU
ROHS directive 2011/65/EU
WEEE directive 2012/19/EU
Security rules EN-61010-1
Instrument
Fixed, Permanently connected
Pollution degree 1 and 2 (without condensation)
Electromagnetic compatibility rules EN-61326-1
EM environment Industrial
CISPR 11
Instrument Class A, Group 1
For a detailed declaration see document 5140 at section
Barberà del Vallès, September 2020
Xavier Juncà - Product Manager
According to directive 2012/19/EU, electronic equipment
must be recycled in a selective and controlled way at the
end of its useful life.
20. CE declaration of conformity