22.2 Accessories

Adapter  for  DIN  rail  mount,  for 

96 x 48 mm panel meters.

22.2.1 Adapter DRA-M

Adapter  96 x 96 mm  for  96 x 48 mm 

panel meters

22.2.2 Adapter KA96

Removable  front  cover  for 

additional  mechanical  and  IP65 

front protection.

22.2.3 Protector KIP

Wall  mount  housing.  Together 

with the KIP protector, offers a full 

IP65 protection. For for 96 x 48 mm 

panel meters.

22.2.4 WME wall housing

Benchtop housing for for 96 x 48 mm 

panel  meters.  Handle  with  three 

selectable 

positions. 

Power 

connector  with  manual  switch  and 

fuse holder.

22.2.5 THM benchtop housing

Set of labels ‘Vdc’, ‘Vac’, ‘Adc’, ‘Aac’, 

‘mVdc’, ‘mVac’, ‘mAdc’, ‘mAac’, ‘%’, 

‘ºC’, ‘ºF’, ‘ph’, ‘m’, ‘cm’, ‘mm’, ‘bar’, ‘psi’, 

‘Pa’, N’, ‘Ω’, ‘KΩ’, ‘W’, ‘kW’, ‘MW’, ‘kV’, 

‘kA’, ‘m/min’, ‘rpm’, ‘l’

(1 set included with each instrument)

22.2.6 Set of units (included)

Summary of Contents for LP4

Page 1: ...www fema es SPECIAL YOUR METER APPLICATIONS Model LP4 USER S MANUAL Loop mA LOOP POWERED PROCESS METER SERIES SPECIAL 5137r01...

Page 2: ...6 13 4Key UP fast access 7 13 5 Tools menu 7 14 Technical specifications 8 15 Error codes 8 16 Mechanical dimensions mm inch 8 17 Precautions on installation 9 18 Warranty 9 19 Factory default paramet...

Page 3: ...d connections Inverted connections will not damage the instrument the loop will remain open and the instrument does not operate display does not light Terminal 2 is not connected Connecting any of the...

Page 4: ...ries parameters and select configuration values Key SQ functions as the ENTER key It selects the menu entry currently displayed At numerical value entries it validates the number displayed Key UP 5 mo...

Page 5: ...r appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates When exiting the fast access menu the instrument returns to normal mode of operation...

Page 6: ...ads wait while performs the reading of the actual input signal value and associates this value to the input low parameter When finished the instrument goes back to the Correction low F Lo menu entry a...

Page 7: ...ect Measure function MEAS to activate an access to visualize the actual input signal value in milliamperes without the scaling 13 5 Tools menu The Tools tool menu groups several functions at the Input...

Page 8: ...isplay display refresh 2 times second acquisition per second 2 acquisitions second memory retention values for maximum and minimum reading are stored every 10 minutes INPUT SIGNAL signals accepted 4 2...

Page 9: ...r than the minimum current needed The instrument is designed to be panel mounted An appropriate ventilation of the instrument must be assured Do not expose the instrument to excess of humidity Maintai...

Page 10: ...of LP4 loop powered meter placed close to the transmitter using the existing loop to the PLC 4 20mA transmitter Units LP4 loop powered meter PLC The LP4 loop powered meter can be directly inserted int...

Page 11: ...2 3Protector KIP Wall mount housing Together with the KIP protector offers a full IP65 protection For for 96x48mm panel meters 22 2 4WME wall housing Benchtop housing for for 96x48mm panel meters Han...

Page 12: ......

Reviews: