Fema LP4 User Manual Download Page 9

 Model LP4

SERIES SPECIAL . LOOP POWERED METERS

www.fema.es 

9

17.  Precautions on installation

This  instrument  is  warranted  against  all  manufacturing  defects  for  a 

period  of  24  months,  as  requested  by  the  European  legislation.  This 

warranty does not apply in case of misuse or accident, and the scope 

of  the  warranty  is  limited  to  repair  of  the  instrument,  not  being    the 

manufacturer responsible for additional damages or additional costs. 

Within the warranty period and after examination by the manufacturer, 

the unit will be repaired or substituted when found to be defective.
Extended warranty available at (see section 4)

18.  Warranty

Scaling 

   Decimal point 

xxxx

   Display low 

0

   Display high 

9000

Display

   Square root 

off

   Average filter 

0

   Steps 

1

   Left zeros 

off

   Memory of maximum 

-1999

   Memory of minimum 

9999

Key ‘UP’ (fast access)

   Memory of maximum 

on

   Memory of minimum 

on

   Measure function 

on

Tools

   Input range

      Input low 

4.00   [mA]

      Input high 

20.00 [mA]

   Brightness 

adaptive

   Password 

off (0000)

This  instrument  has  been  designed  and  verified  conforming  to  the 

61010-1 CE Security Regulation, for industrial applications. Installation 

of this instrument must be performed by qualified personnel only. This 

manual contains the appropriate information for the installation. Using 

the instrument in ways not specified by the manufacturer may lead to a 

reduction of the specified protection level. Disconnect the instrument 

from  all  external  circuits  before  starting  any  maintenance  and  /  or 

installation action.
The instrument does not have a general switch and will start operation as 

soon as signal is connected and the current is higher than the minimum 

current needed.
The  instrument  is  designed  to  be  panel  mounted.  An  appropriate 

ventilation  of  the  instrument  must  be  assured.  Do  not  expose  the 

instrument  to  excess  of  humidity.  Maintain  clean  by  using  a  humid 

rag and do NOT use abrasive products such as alcohols, solvents, etc. 

General  recommendations  for  electrical  installations  apply,  and  for 

proper functionality we recommend: if possible, install the instrument far 

from electrical noise or magnetic field generators such as power relays, 

electrical motors, speed variators, ... If possible, do not install along the 

same conduits power cables (power, motor controllers, electrovalves, ...) 

together with signal and/or control cables. In case of fire, disconnect 

the instrument from the power line, fire alarm according to local rules, 

disconnect  the  air  conditioning,  attack  fire  with  carbonic  snow,  never 

with water.

Instrument conforms to CE rules and regulations. 

19.  Factory default parameters

Manufacturer 

FEMA ELECTRÓNICA, S.A.

 

 

Altimira 14 - Pol. Ind. Santiga

 

 

E08210 - Barberà del Vallès 

 

 

BARCELONA  - SPAIN

 

 

www.fema.es - [email protected]

Products  

LP4

The manufacturer declares that the instruments indicated comply with the 

directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU

 

ROHS directive 2011/65/EU

 

WEEE directive 2012/19/EU

Security rules EN-61010-1

Instrument  

Fixed, Permanently connected

 

Pollution degree   1 and 2 (without condensation) 

 

Electromagnetic compatibility rules EN-61326-1

EM environment  Industrial

 

CISPR 11  

Instrument Class A, Group 1

For a detailed declaration see document 5140 at section 

4

.

 

Barberà del Vallès, September 2020

 

Xavier Juncà - Product Manager

According to directive 2012/19/EU, electronic equipment 

must be recycled in a selective and controlled way at the 

end of its useful life.

20.  CE declaration of conformity

Summary of Contents for LP4

Page 1: ...www fema es SPECIAL YOUR METER APPLICATIONS Model LP4 USER S MANUAL Loop mA LOOP POWERED PROCESS METER SERIES SPECIAL 5137r01...

Page 2: ...6 13 4Key UP fast access 7 13 5 Tools menu 7 14 Technical specifications 8 15 Error codes 8 16 Mechanical dimensions mm inch 8 17 Precautions on installation 9 18 Warranty 9 19 Factory default paramet...

Page 3: ...d connections Inverted connections will not damage the instrument the loop will remain open and the instrument does not operate display does not light Terminal 2 is not connected Connecting any of the...

Page 4: ...ries parameters and select configuration values Key SQ functions as the ENTER key It selects the menu entry currently displayed At numerical value entries it validates the number displayed Key UP 5 mo...

Page 5: ...r appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates When exiting the fast access menu the instrument returns to normal mode of operation...

Page 6: ...ads wait while performs the reading of the actual input signal value and associates this value to the input low parameter When finished the instrument goes back to the Correction low F Lo menu entry a...

Page 7: ...ect Measure function MEAS to activate an access to visualize the actual input signal value in milliamperes without the scaling 13 5 Tools menu The Tools tool menu groups several functions at the Input...

Page 8: ...isplay display refresh 2 times second acquisition per second 2 acquisitions second memory retention values for maximum and minimum reading are stored every 10 minutes INPUT SIGNAL signals accepted 4 2...

Page 9: ...r than the minimum current needed The instrument is designed to be panel mounted An appropriate ventilation of the instrument must be assured Do not expose the instrument to excess of humidity Maintai...

Page 10: ...of LP4 loop powered meter placed close to the transmitter using the existing loop to the PLC 4 20mA transmitter Units LP4 loop powered meter PLC The LP4 loop powered meter can be directly inserted int...

Page 11: ...2 3Protector KIP Wall mount housing Together with the KIP protector offers a full IP65 protection For for 96x48mm panel meters 22 2 4WME wall housing Benchtop housing for for 96x48mm panel meters Han...

Page 12: ......

Reviews: