1.13
Full configuration menu
Press ‘SQ’
(
<
)
for 1 second to access the ‘Configuration menu’. See
for a description of each menu entry.
Function
mode
Preset
Preset value
-1999 to 9999
Counting
direction
Up
Down
Function
on channel ‘B’
Function assigned to
channel ‘B’. Select
-
ing a ‘B’ function
automatically acti
-
vates connection type
‘Con.2’ (see section
Function B.1
control up / down
Next menu entry gives access to the configuration parameters of the ‘
channel ‘B’
function
’ (‘
Fn.b
’) previously selected. If no function has been selected, menu entry
indicates ‘
Fn.b.n
’. Following is an explanation for menus ‘
Fn.b.1
’ to ‘
Fn.b.6
’.
Function B.2
cycles
‘on alarm 1’
‘on alarm 2’
‘on alarm 3’
on ‘reset’
Function B.3
accumulated
Format
Count
Function B.4
exceeded
Format
View format
Configuration
Flash
‘Flash on stop’
‘Flash on start’
On power-up
Delay
Seconds
Reset
State
Rear reset
activates by edge
activates by level
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0.00 to 99.59
0.00 to 99.59
0.00 to 99.23