Functions of GT16 transmitter: 

4-channel  transmitter,  accelerator  channel,  direction  channel,  AUX2  key  channel  and 

aux1 three-stage switch; st-trim, th-dr, st-dr,st-rev, th-epa and st-epa can be set;   

EPA setting function 

Trigger conditions: 

Start + back + turn right 

Function Description: 

Take setting forward EPA as an example. 

After the EPA setting function is triggered, the red LED light flashes quickly, At this time, 

pull the accelerator rocker to make it in the forward position. At this time, Rotate the th trim 

knob to adjust the set EPA value. After setting, return the throttle rocker to the center, and 

the red LED off, indicating  that the setting parameters are completed.  The same is true for 

other EPA settings. 

ST EPA parameter setting range:0% ~ 120%.   

TH EPA parameter setting range:0% ~ 150%.   

All EPA = 100% by default 

Calibration function 

Trigger conditions: 

Turn on + front + turn right 

Function Description: 

After  the  function  is  triggered,  red  LED  lights  flash  slowly  at  the  same  time.  The  indicator 

enters the calibration state. 

Then push and pull the  accelerator rocker and select the steering wheel for front, rear, left 

and  right  calibration.  The  front,  rear,  left  and  right  calibrations  are  in  no  order.  After 

completing the front, rear, left and right calibration, center the accelerator rocker and runner, 

and toggle the st rev switch four times to calibrate the neutral point. After the calibration is 

successful, the red LED lights are on in turn, indicating that the machine is turned on normally 

and enters the normal working state. 

Binding function 

Trigger conditions: 

Power off + press and hold the power button over 3s. 

Function Description: 

When the red LED flashes rapidly, it indicates that the transmitter has entered the frequency 