For your safety.
Read all safety warnings and all instruc-
tions provided with the magnetic drill
stand or the power tool.
Failure to fol-
low the warnings and instructions may result in electric
shock, fire and/or serious injury.
Save all safety warnings and instructions for future refer-
ence.
Do not use this product before you have thor-
oughly read and completely understood this
Instruction Manual and the enclosed “General
Safety Instructions” (document number
3 41 30 054 06 1
). The documents mentioned should
be kept for later use and enclosed with the product,
should it be passed on or sold.
Please also observe the relevant national industrial safety
regulations.
Intended use of the magnetic drill stand:
Magnetic drill stand for holding a drive motor, for drilling
with core drill bits and solid drill bits, reaming and tapping
on materials with surfaces suitable for magnets in
weather-protected environments using the application
tools and accessories recommended by FEIN.
Special safety instructions.
Pull the plug from the mains receptacle and/or remove the
battery before making adjustments on the tool or changing
tool accessories.
Unintentional switching on of the power
tool is the cause of many accidents.
Before mounting the power tool, install the magnetic drill
stand correctly.
The correct installation is important in
order to prevent the risk of the drill stand folding
together.
Fasten the power tool securely to the magnetic drill stand
before using it.
Slipping off of the power tool on the mag-
netic drill stand can lead to loss of control.
Do not overload the magnetic drill stand.
Overloading the
magnetic drill stand can cause it to tip over.
Wear personal protective equipment. Depending on appli-
cation, use face shield, safety goggles or safety glasses. As
appropriate, wear dust mask, hearing protectors, gloves
and workshop apron capable of stopping small abrasive or
workpiece fragments.
The eye protection must be capable
of stopping flying debris generated by various operations.
The dust mask or respirator must be capable of filtrating
particles generated by your operation. Prolonged expo-
sure to high intensity noise may cause hearing loss.
When there is danger of falling down, secure the magnetic
drill stand using the provided lashing strap; especially
when working aloft, on vertical building elements or over-
head.
In case of a power failure or when the mains plug
is pulled, the magnetic holding power is not maintained.
Prevent (cooling) liquids from penetrating into the mag-
netic drill stand, especially when working on walls and ceil-
ings.
Penetrating liquids can lead to danger of an electric
shock.
Operate the magnetic drill stand only from socket outlets
with the earthing contact according to regulations. Only use
undamaged supply cords and regularly checked extension
cords with earthing contact.
A protective conductor with-
out continuity can lead to electric shock.
Do not direct the power tool against yourself, other persons
or animals.
Danger of injury from sharp or hot application
tools.
Do not rivet or screw any name-plates or signs to the mag-
netic drill stand.
If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Do not use accessories not specifically intended and recom-
mended for the magnetic drill stand by the manufacturer.
Just because the accessory can be attached to your mag-
netic drill stand, it does not assure safe operation.
Before putting into operation, check the mains connection
and the mains plug for damage.
Recommendation: Always operate the power tool via a
residual current device (RCD) with a rated residual current
of 30 mA or less.
Operating instructions.
When a power tool is mounted that is
not intended for use with the magnetic
drill stand, the magnetic drill stand can
tip over.
Use the magnetic drill stand suitable for the performance
characteristics of your drive motor.
Please make sure that the contacting surface for the mag-
netic foot is level, clean and rust-free. Remove any var-
nish or primer.
Use the magnetic drill stand only with the magnetic foot
switched on.
When working on materials that are not magnetizable,
suitable fixation devices, obtainable as accessories from
FEIN, e. g. suction plate, vacuum plate or pipe-drilling
device must be used.
Character
Unit of measure,
international
Unit of measure,
national
Explanation
mm
mm
Adjustment range
l x w
mm
mm
Magnetic foot plate dimensions
mm
mm
d
1
= collar diameter of drive motor
m, s, kg, A, mm, V,
W, Hz, N, °C, dB,
min, m/s
2
m, s, kg, A, mm, V,
W, Hz, N, °C, dB,
min, m/s
2
Basic and derived units of measure from the inter-
national system of units
SI
.
WARNING
WARNING
3 41 01 128 06 0.book Seite 17 Mittwoch, 23. Dezember 2015 8:25 08
Summary of Contents for MBS 16
Page 4: ...4 1 2 3 4 5 6 MBS16 3 41 01 128 06 0 book Seite 4 Mittwoch 23 Dezember 2015 8 25 08...
Page 8: ...8 MBS16 MBS23 MBS23F MBS32F 3 41 01 128 06 0 book Seite 8 Mittwoch 23 Dezember 2015 8 25 08...
Page 12: ...12 MBS16 MBS23 MBS23F MBS32F 3 41 01 128 06 0 book Seite 12 Mittwoch 23 Dezember 2015 8 25 08...
Page 66: ...66 zh CM FEIN FEIN 3 41 01 128 06 0 book Seite 66 Mittwoch 23 Dezember 2015 8 25 08...