TST
Startup
WUI
FEIG ELECTRONIC GmbH
Page 6 of 20
WUI_Inbetriebnahme2_GB.doc
Safety edge input
for electric safety edges with 1.2k
Ω
or 8.2k
Ω
terminal resistance
and for dynamic optical systems
Relay outputs
if inductive loads are switched (e.g. further relays or brakes), they
must be equipped with corresponding noise suppresion
measures (free-wheeling diodes, varistors, RC elements)
Relays K1, K2:
⇒
24VDC / 500 mA
⇒
230 VAC / min. 0.1 A / max.
80 W
potential-free switching, change-
over contact
Contacts which have been
used once for power switching
can no longer switch extra-low
voltage
Relays K3, ... K14:
⇒
24VDC / 1A
⇒
120 VAC / 0,5A
potential-free switching, N.O.
contact
Contacts which have been
used once for power switching
can no longer switch extra-low
voltage
Drive output:
3x 400VAC, max. 2.2 kW for AC-3
Reversing contactor is prepared for operating three-phase drives
Max. length of the motor cable: 30m
electromechanical brake 230 V
AC
-control via switched motor phase and N
Operating temperature range:
-10...+50°C
Storage temperature range
-20...+70°C
Air humidity
up to95% not condensating
Mains cable installation
Y, the mains cable must only be replaced by the manufacturer or
his after-sales service or by another qualified person
Equipment mobility
stationary
Protection class
Protection class I
Equipment type
Motor appliance, external motor is not part of the delivery from
FEIG ELECTRONIC GMBH
Vibration
low vibration installation, e.g. on a brick wall
Protection class
IP54 (IP65 by replacing CEE connection and sealing cable
entries)
All unused cable entries must be closed.
Weight
ca. 2.8 kg
Directives
Standards:
EMV-Directive:
89/336/EWG
modified by:
91/263/EWG
92/031/EWG
93/068/EWG
EN 50081-1 / 03.93:
interference emissions, residential
area
EN 50081-2 / 03.94:
interference emissions, industrial area
EN 61000-6-2 / 2001:
interference resistance, industrial area
Low voltage directive:
73/023/EWG
modified by:
93/068/EWG
EN 60335-1 / 2003:
Safety of electrical appliances for
domestic use and similar purposes /
Part 1
Prototype tested according to:
EN12453 / 2001:
Usage safety of power-operated gates
– requirements
EN12445 / 2001:
Usage safety of power-operated gates
– test methods
Applied national technical
specifications concerning the
directives mentioned above
EN12978 / 2003:
Gates – safety equipment –