TST
Startup
WUI
FEIG ELECTRONIC GmbH
Page 14 of 20
WUI_Inbetriebnahme2_GB.doc
9
General operating instructions for parameterisation
Starting parameterisation mode
1.
Switch on the
gate control
system
Switch on control system
the first decimal position flashes
when service mode is active
Content of the display depends on
the status of the control system
.
. . .
2.
Å
STOP
(permanent)
Press Stop button and keep it
pressed
pending messages are displayed,
e.g.;:
E
.
2 0 1
3.
¿
Up
(permanent)
Press Up key and keep it
pressed
after ca. 2 seconds waiting:
In parameterisation mode
P
.
0 0 0
Parameter selection when parameterisation mode is active
¿
À
UP
or
DOWN
select desired parameter
A T T E N T I O N:
Not all parameters are directly
visible or modifiable depending
on password and type of
security level set
the parameter value can be displayed
or modified (see below)
display varies according to the
selection
P
.
. . .
Parameter editing for selected parameter
1.
Control system in
parameterisation mode
Display of the desired parameter
name
P
.
0 1 0
2.
Å
STOP (short)
Open the parameter
the current parameter value is
displayed:
5
3.
¿
Up
Up key for increasing
parameter value
if the current parameter value in force
is changed, the decimal positions
flash
6
or
À
Down
Down key for reducing the
parameter value
4
4.
Å
STOP (long)
save amended parameter value
the parameter counts as saved when
no positions are flashing any more
6
or
STOP (short)
discard amended parameter
value
cancellation, the original parameter
value is displayed again
4
5.
Å
STOP (short)
for changing to the display of
the parameter name
Display parameter name
P
.
0 1 0
Leaving parameterisation mode
Å
STOP (long)
parameterisation mode is
stopped immediately, gate
operation is active again
The last saved value is obtained
automatically
. . . .
Reset the control system
Å
+
¿
+
À
press simultaneously and keep pressed for ca. 3 seconds.