TST
Startup
FU3E
FEIG ELECTRONIC GmbH
Page 28 of 29
FU3E_Inbetriebnahme_7_GB.doc
12.2 Information messages
General messages
STOP
Stop
/ Reset state, wait for next incoming command
_Eu_
End position Lower Eu
≡
Eu
≡
End position Lower locked
→
no raising possible (e.g., lock-door)
ZUF
@
Closing active
-Eo-
End position Upper Eo
≡
Eo
≡
End position Upper locked
→
no closing possible (e.g., safety edge)
@
AUF
Opening active
-E1-
End position middle E1 (intermediate stop position)
≡
E1
≡
End position middle locked
→
no closing possible (e.g., safety edge)
FAIL
Fault
→
only deadman travel is possible, possibly automatic opening
EICH
Calibration
→
Setting the end positions in deadman travel
(for absolute encoder )
→
Start procedure using STOP key
≡
NA
≡
E-Stop
→
No travel possible, hardware safety chain interrupted
NOTF
E-travel
→
Deadman travel without taking into account safeties, etc.
'Hd'
Manual
→
Deadman mode
ParA
Parameterizing
SYNC
Synchronization
(incremental encoder / limit switch
→
Pos.unknown)
'Au'
Automatic
→
indicates change from „Manual“ to „Automatic“ status
'Hc'
Semi-automatic
→
indicates change from „Manual“ to „Semi-automatic“
FU3E
Initial display after power up
(Power Up and self-test)
Status messages during calibration
E.i.E.u.
Calibration of the End position Lower requested (in deadman travel)
E.i.E.o.
Calibration of the End position Upper requested (in deadman travel)
E.i.E.1.
Calibration of the intermediate position E1 (in deadman travel)
Status messages during synchronization
S.y.E.u.
Synchronization of End position Lower requested
(Deadman or wait for start condition)
S.y.E.o.
Synchronization of End position Upper requested
(Deadman or wait for start condition)
S.y.E.1.
Synchronization of intermediate stop position E1 (in deadman)
S.y.op
Automatic open until mechanical stop, then automatic synchronization of End position
Upper
S.y.cL
Automatic close taking into account safeties until mechanical stop, then automatic
synchronization of End position Lower
S.y.c
≡
Automatic close is locked due to request
Å
Status messages during deadman
Hd.cL
Deadman close (membrane key: CLOSE)
Hd.oP
Deadman open (membrane key: OPEN)
Hd.Eu
End position Lower reached, no further deadman close possible
Hd.Eo
End position Upper reached, no further deadman open possible
Hd.Ao
Outside of permitted Eo position (no deadman open possible)
Information messages during Automatic mode
I.080
Maintenance required soon / service counter nearly expired
I.100
Speed when reaching upper end position too high
I.150
Speed when reaching lower end position too high
I.160
Continuous CLOSED still active
I.170
Forced opening being performed
I.185
Wait for acknowledgement (operator call), display flashes
I.199
Door cycle not plausible (re-initialize
Æ
Parameters)
I.200
Reference position corrected or recognized (after calibration)
I.201