TST
Startup
FU3E
FEIG ELECTRONIC GmbH
Page 21 of 29
FU3E_Inbetriebnahme_7_GB.doc
P.
[Unit]
Range
Diagnostics
Default
910
0..22
Selecting display mode
(request by STOP button or during motor movement)
0: Controller sequence (Automatic mode)
1: [Hz] current rotary field frequency
2: [A] current motor current (> 1A)
3: [V] current motor voltage
4: [A] current link current (effective current)
5: [V] link voltage
6: [°C] final stage temperature in °C
7: [°F] final stage temperature in °F
8: last measured run time (1/10 to 99.9s, 1/1 starting at 100s)
For electronic limit switches only:
9: [Inc] current position progress
10: [Inc] current reference position
11: [dig] current channel 1 value of absolute encoder
12: [dig] current channel 2 value of absolute encoder
13: [dig] current reference voltage (2.5V)
14: 14: Temperature in housing in [°C]
15: 15: Temperature in housing in [°F]
16: Reserved
17: Reserved
18: Rotation speed of the TST PD shaft
)
only with TST PD
19: Reserved
20: Reserved
21: Number of position requisition without answere
22: Number of wrong received signs in TST PD encoder
(activates also the output in P.955)
0
920
Eb 1
Eb 2
Eb 3
Eb 4
Eb 5
Eb 6
Eb 7
Eb 8
Ebcl
Eb -
Display error memory / Faults
⇒
Open by pressing Stop key again,
⇒
Change by pressing Open/Close key
⇒
Quit by pressing Stop key.
⇒
Exit using cancel "EB-".
•
Eb
1
→
Error message 1 (most current)
or Er--
•
Eb
2
→
Error message 2
or Er--
•
Eb
3
→
Error message 3
or Er--
•
Eb
4
→
Error message 4
or Er--
•
Eb
5
→
Error message 5
or Er--
•
Eb
6
→
Error message 6
or Er--
•
Eb
7
→
Error message 7
or Er--
•
Eb
8
→
Error message 8
•
Ebcl
→
Clear entire error memory
•
Eb
-
→
Cancel
(Display noEr: no error)
Eb 1
925
Software version display
930
[s]
0..120.0
Motor run-time during last door move
940
[V]
Line supply voltage display