2.4.6 Power Saving Mode
If the Power Saving Mode is activated the display turns off if there was no activity on the user interface for more
than 30 s. The counter function continues to run in the background. The Power Saving Mode can be adjusted using
thefollowing menu:
Display
State Setting
1234
Normal Operation
M long
→
SyS
→
S
oc
M 9 x short
→
LoPo
= power saving mode
LoPo
(alternating)
off
on
Display Power Saving
Mode
•
OFF(Display
on)
•
ON (Display off)
M short
→
next, next menu item
M long
→
End
= return to normal operation
∧
or
∨
→
change function
off
on
(flashing)
Change Function
∧
→
off
→
on
∨
→
on
→
off
M short
→
cancel
M long
→
Skor
= save
2.5 Factory
Setting
All parameter and counter can be reset to factory default values using the following procedure:
Display
State Setting
Turn off power supply for more than 2 seconds
1234
(flashing)
Return after power
failure
Press two buttons simultaneously
→
Err
Err
(flashing)
System error
M long
→
Skor
= reset to factory default
→
0000
flashing = factory default
M short
→
cancel, restart without factory default
settings
After a reset to factory default values all parameters are set to the following (see table below) and all counter are
set to zero (0).
Parameter Setting
Ouk
Relay output
Auko
Automatic
S
oc
Switch threshold
0
0 = Open Space Counting
HyS
Counter hysteresis
1
one vehicle
SkP¯
Upper counter level
9999
9999
SkP_
lower counter level
-999
-999
InP1
Function Input 1
Add
incrementing
InP2
Function Input 2
Sub
decrementing
InP3
Function Input 3
Add
incrementing
InP4
Function Input 4
Sub
decrementing
rEL
Output functionality
oc
.
on
Normaly Open Mode
LoPo
Power Save Mode
oFF
off, Display continuously activated