![Feig Electronic OBID i-scan ID ISC.PR101 Manual Download Page 71](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-pr101/obid-i-scan-id-isc-pr101_manual_3908001071.webp)
OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH101
FEIG ELECTRONIC GmbH
Page 71 of 131
H60301-3e-ID-B.doc
6.1.10. [0x29] Write DSFI
This command writes the DSFID to one ore more Transponders.
The supported ISO15693 Host commands depend on the different ISO15693 Transponder types,
which are described in chapter
9.1. Supported ISO15693 Host commands for ISO15693 Transpon-
ders
.
REQUEST-DATA
4
5
(6...13)
6 / (14)
0x29
MODE
UID
DSFID
RESPONSE-DATA (STATUS = 0x95)
5
ISO15693
ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DSFID:
Data Storage Format Identifier of the Transponder.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
Note:
•
This command is only available for ISO15693 Transponders.