3.1. CFG0: Reserved
The configuration block CFG0 is reserved for future use.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
3.2. CFG1: Interface
The parameters of the CFG1 configuration block contain the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
1
TRANS-
FORM
1
ADVANCED
MODE
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x00
0x00
0x00
38400 Baud
e,8,1
USB-Ver-
sion
0x00
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
0x00
0x00
INTERFACE
READER -
MODE
Default
0x1E
0x01
MR/PR: 0x00
PRH: 0x01
3 sec.
USB-Ver-
sion
0x1E
0x00
COM-ADR:
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface, es-
pecially for applications with the RS485 interface.
Notes:
•
Do not configure address 255!