10.3. Supply voltage
The supply voltage (230VAC / 50Hz or. 115VAC / 60 Hz) has to be connected to the terminals L
and N of the power unit.
The unit has been preset by the manufacturer to a supply voltage of 230V / 50 Hz. The slide switch
on the power supply unit DPR-60 provides the possibility to switch to a distribution voltage of 115V/
60 Hz.
The power supply line has to be layed separately to the other access lines, as well as outside the
enclosure.
Note:
•
To meet national requirements for radio frequency devices the power supply line must
be fitted with the supplied EMC ring core
∅
∅
∅
∅
41 mm x 15 mm. The power supply line must
be wound around the ring core for at least 6 turns. The distance between the Reader
termination and the ring core should be maximum 10 cm.
•
The 24V-Output of the internal power supply unit may not be used for the supply of ex-
ternal circuits
Protection ground connection:
To form the protection ground connection the corresponding green/yellow lead
on the feed line (1) must be crimped together with the preassembled
green/yellow line (2) in one of the supplied duo wire end ferrules. The connection
is then made at the corresponding protection ground terminal of the power sup-
ply.
N L
Protection ground connection !!!
See below !!!
(1)
(2)