Installation
The CPR.03.20-CD is designed to be wall-mounted with or without a 60 mm flush-mounting box
4.1
Mounting
•
The reader should not be mounted directly onto conductive materials, such as metal surfaces,
metal frames (reinforcement) or metal-plated surfaces, as these surfaces will reduce the
reader's range. The clearance to such surfaces should be at least 30 mm.
•
The distance between readers of the same design should not be less than 50 cm.
•
Before final installation, the planned installation site should be checked for suitability.
•
Only install the reader after successful commissioning. The power supply must be discon-
nected for configuration (see also:
4.3 Configuration
).
•
Use the screws provided (3.2 x 25 mm) for installation on 60 mm DIN flush-mounting boxes.
•
For other installation methods use 3 mm countersunk-head screws to DIN 963 or with a coun-
tersunk head max. diameter of head 5.6 mm.