5
Normal Operating Mode
Idle State (no Transponder detected):
In idle state the reader is searching permanent for a Transponder and red LED is on.
Transponder detected:
After a Transponder is detected by the CPR.03.20-CD the data's are transmitted via the
configured interface once and the beeper sounds for a short time. At the same time the
red LED turns off for 2 seconds.
To transmit the data's a second time the Transponder must leave the detection field of the
CPR.03.20-CD for more then 1,5 seconds.
UID Length Error
If the Transponder UID is shorter than configured in CPR.03.20-CD a length error is sig-
nalized with 2 short beeps. In this case no data's are transmitted via data-/clock interface.
5.1
Digital Inputs
LED red:
Activates the red LED, as long as the input is connected to GND.
LED green:
Activates the green LED and deactivates the red LED, as long as the input is connected to
GND.
Beeper:
Activates the beeper LED, as long as the input is connected to GND.
Hold:
Will not accept a transponder, as long as the input is connected to GND.