OBID
®
classic-pro
Installation
ID CPR.03.20-CD
FEIG ELECTRONIC GmbH
Page 21 of 24
M60100-2de-ID-B.doc
E N G L I S H
4.2
Connection
Colour
Function
Description
red
Vcc (+9 to 15 V DC)
black
GND*
Power Supply
green
Data / Data0
white
Clock / Data1
violet
CLS / Card Present
Clock/Data interface
(magnetic strip/ Wiegand)
grey
LED green
brown
LED rot
yellow
Beeper
blue
Hold
digital input**
pink
RS232-TTL (Rx)
red / blue
RS232-TTL (Tx)
Service and Data Output
Interface
grey / pink
- N.C. -
*) If the power is not supplied via the controller the power supply GND must be connected
to the controller GND.
**) The digital inputs may only be wired to ground. Wiring to an external power supply may
destroy the input.
Controller
Vcc
Data / Data0
Clock / Data1
CLS
LED green
LED red
Beeper
Hold
GND
red
green
white
violet
grey
brown
yellow
blue
black
pink
red/blue
+9..15 V DC
max. 150 m
RS232-TTL
RS232
max. 3 m
RS232 TxD
RS232 RxD