IDENTIFICATION
ID HyWEAR compact
11 Configuration Parameters
Page 27 of 41
11.3 Scan Settings
11.3.1 Scan-Time RFID
Logical Name
AirInterface.ScanTime
Description
Defines the timespan the reader scans for an RFID tag.
Possible Values
1...65535
Default Value
5
Unit
* 10 ms
Reset Required
Soft
11.3.2 Scan-Time Barcode
Logical Name
Barcode.ScanTime
Description
Defines the timespan the reader scans for a barcode.
Possible Values
1...255
Default Value
30
Unit
* 100 ms
Reset Required
Soft
11.3.3 Scan Engine
Logical Name
OperatingMode.ScanMode.DataSource.Engine
Description
Defines the engine from which data is to be read. If two engines are selected, the second engine is used only when the
first engine timed out. The default value depends on the version of the reader.
Possible Values
0x0001: RFID first, Barcode second
0x00FF: RFID only
0x01FF: Barcode only
Default Value
0x0001
Unit
-
Reset Required
Hard
11.3.4 Scan Interface
Logical Name
OperatingMode.ScanMode.Interface
Description
Defines the interface, which is used to send the scanned data to the host.
The demo mode is for demonstration purposes only. It allows scanning without an active Bluetooth or WiFi connection.
The status of a scan is indicated by the outputs (vibrator/buzzer/LED).
Possible Values
0x00: Demo
0x01: Bluetooth SPP
0x02: Bluetooth HID
0x11:WiFi
Default Value
0x02
Unit
-
Reset Required
Hard