ORIGINAL INSTRUCTIONS > EN

11

NOTE

Weather will affect engine oil and engine performance. Change the type of engine oil used based on

weather conditions to suit the engine needs.

NOTE

Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not increase

the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold ambient <5°C

(41°F)

NOTE:

We consider the first 5 hours of run time to be the break-in period for the unit. During the break in

period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator

windings to heat and cool. Adjusting the load will also cause engine speed to vary and help seat piston

rings. After the 5 hour break-in period, change the oil

NOTE

Weather will affect engine oil and engine performance. Change the type of engine oil used based on

weather conditions to suit the engine needs.

NOTE

Synthetic oil may be used after the 5 hour initial break-in period. Using synthetic oil does not increase

the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold ambient <5°C

(41°F)

Add Fuel (Gas)

Summary of Contents for FGHi3500

Page 1: ...IONS EN 1 LOW POWER DUAL FUEL GENERATOR MODEL FGHi3500 ORIGINAL INSTRUCTIONS BUILDER SAS ZI 32 rue Aristide Berg s 31270 Cugnaux France Made in P R C 2021 Warning Please read the manual carefully befo...

Page 2: ...L INSTRUCTIONS EN 2 CONTENTS 1 SAFETY WARNINGS 3 2 COMPONENT IDENTIFICATION 9 3 ASSEMBLY 9 4 OPERATION 14 5 MAINTENANCE AND STORAGE 18 6 SPECIFICATIONS 22 7 TROUBLESHOOTING 23 8 DECLARATION OF CONFORM...

Page 3: ...that is well ventilated and make sure that there is at least 1 5 meters between the generator and the walls of the building or other equipment Do not place flammable liquids or gases near the generato...

Page 4: ...condition Keep in flammable away Warning when you start the generator with the cord watch out for sudden changes in the rotation of the motor Risk of wounding Never cover the generator when it is run...

Page 5: ...e with IEC 60245 4 or the equivalent should be used The user shall conform to regulations of electrical safety applicable to the place where the generating sets are used The user must respect the requ...

Page 6: ...enerator To avoid electric shock you must follow the following instructions Do not touch the generator with wet hands Do not run the generator under rain or snow Do not run the generator near water Co...

Page 7: ...ire or explosion if ignited Gas is a liquid fuel but its vapors can ignite Gas is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes Gas has a distinctive odor this w...

Page 8: ...sound power level No naked flames Ground connection It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates...

Page 9: ...funnel 1 Spark plug socket 1 Automotive style battery charge cables 1 1 Carrying Handle 2 Fuel Level vent Turn this valve to the On position to supply air to the tank 3 Fuel Cap Remove to add fuel 4 R...

Page 10: ...a result of failure to follow these instructions will void your warranty NOTE Recommended oil type is 10W 30 automotive oil 1 Place the generator on a flat level surface 2 Loose the cover screw and r...

Page 11: ...or the unit During the break in period stay at or below 50 of the running watt rating and vary the load occasionally to allow stator windings to heat and cool Adjusting the load will also cause engine...

Page 12: ...ore water than gasoline alone These blends can eventually separate leaving water or a watery goo in the tank fuel valve and carburetor With gravity fed fuel supplies this compromised fuel can be drawn...

Page 13: ...storing turn off the cylinder valve and fuel valve and disconnect the cylinder Plug the outlet usually by a plastic protective cap if one is available Keep cylinders away from heat and ventilated when...

Page 14: ...xhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning generator Failure to follow proper safety precautions may void manufacturer s war...

Page 15: ...resistance is felt and then pull rapidly 7 Do not over choke Allow the engine to warm up several seconds before gradually pushing the choke to the RUN position NOTE Keep choke in Choke position for o...

Page 16: ...effects by doing one of the following Exchanging fuel tanks to allow the first tank to warm up repeating as necessary Placing the LPG container at the end of the generator near the handle where engine...

Page 17: ...necessary for your purposes I Select the electrical devices you plan on running at the same time 2 Total the running watts of these items This is the amount of power you need to keep your items runnin...

Page 18: ...warm Refer to the oil specification to select the proper grade of oil for your operating environment 1 Remove oil fill cap dipstick 2 Use pliers to slide the spring clamp down the oil drain hose and p...

Page 19: ...minate the fuel system Use a damp cloth to clean exterior surfaces of the engine Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the engine S...

Page 20: ...around air intake and muffler Check hose for leaks First 5 hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hot environments Every 100 ho...

Page 21: ...avoid accidental or unintended ignition of your remote start generator during periods of storage the following precautions should be followed When storing the generator for short periods of time make...

Page 22: ...s needed your product may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the product is exposed to temperatures outside this range during storage it should be bro...

Page 23: ...Hi3500 Serial number 220201252740 20201252827 Complies with the provisions of the Directive machinery 2006 42 CE and national laws transposing it Also complies with the following European directives E...

Page 24: ...the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information...

Page 25: ...before dropping of the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is com...

Page 26: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Reviews: