background image

 

 

 

  Perform periodic maintenance and resolve problems that appear immediately. Do not run the 

generator before correcting any fault detected. 

  The generator uses a system of air-cooling, and it is necessary to clean its components regularly, 

including the grilles, the cover of the fan and the fan itself so as to ensure cooling. 

  Keep the fuel filter clean, and change the oil of the motor regularly. 

  Periodically check the installation of the connections and the tightness of the fixations, re-tightening 

them if necessary. 

  Clean the components of the air filter periodically, and replace the air filter when necessary. 

  Remove any electrical equipment that is plugged in before starting or stopping the generator. 

  Before transporting the generator, you must empty the fuel tank. 

  Maintenance and repair of the generator must be carried out by a qualified technician from an 

authorized after-sales service center. 

Warning: when you start the generator with the cord, watch out for sudden changes in the rotation of the 

motor!!!  Risk  of  wounding!!!  Never  cover  the  generator  when  it  is  running.  The  cut-out  mounted  on  the 

generator has the aim of reducing the risk of electric shock. If it needs to be replaced with another cut-out, 

the  latter  must  correspond  to  the  technical  specifications  of  the  generator.  Due  to  important  mechanical 

constraints,  it  is  necessary  to  use  a  flexible  sheathed  cable  with  a  strong  rubber  protective  layer 

(conforming  to IEC  245-4)  or  a similar  cable.  If using  an  electrical  extension  cable,  the total  length  of the 

extension must not exceed 60m when the section of the wire is 1.5mm

2

 and must not exceed 100m when 

the section of the wire is 2.5mm

2

1.2 ADDITIONAL REQUIREMENTS FOR LOW-POWER 
GENERATING SETS FOR USE BY LAYMEN 

  Protect children by keeping them at a safe distance from the generating set. 

  Fuel is combustible and easily ignited. Do not refuel during operation. Do not refuel while smoking 

or near naked flames. Do not spill fuel. 

  Some  parts  of  the  internal  combustion  engine  are  hot  and  may  cause  burns.  Pay  attention  to  the 

warnings on the generating set. 

  Engine  exhaust  gases  are  toxic.  Do  not  operate  the  generating  set  in  unventilated  rooms.  When 

installed  in  ventilated  rooms,  additional  requirements  for  fire  and  explosion  protection  shall  be 

observed. 

  Before  use,  the  generating  set  and  its  electrical  equipment  (including  lines  and  plug  connections) 

should be checked to ensure that they are not defective. 

  Protection against electrical shock depends on circuit breakers specially matched to the generating 

set. If the circuit breakers require replacement, they should be replaced with a circuit breaker having 

identical ratings and performances characteristics. 

  Due to high mechanical stresses, only tough rubber-sheathed flexible cable (in accordance with IEC 

60245-4) or the equivalent should be used. 

  The  user  shall  conform  to  regulations  of  electrical  safety  applicable  to  the  place  where  the 

generating sets are used. 

Summary of Contents for FG3000-A

Page 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG3000 A USER GUIDE CAUTION Read the instructions before using the product...

Page 2: ...5 GENERATOR USE 10 6 PRE OPERATION CHECK 13 7 STARTING STOPPING THE ENGINE 15 8 MAINTENANCE 16 9 TRANSPORTING AND STORAGE 20 10 TROUBLESHOOTING 22 11 WIRING DIAGRAM 23 12 SPECIFICATIONS 24 13 EC DECLA...

Page 3: ...ing area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get caught in the machinery...

Page 4: ...d cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total length of the extension must not exceed 60m when the section o...

Page 5: ...propriate recipient and sheltered from any sources of fire Carry out filling in a safe place and slowly open the fuel cap to release the pressure which has built up inside the tank Wipe up any drops o...

Page 6: ...o function with a voltage tolerance of 10 or a frequency tolerance of 3 compared with those of the generator 1 5 PROTECTION OF THE ENVIRONMENT You must periodically check the silencer Before doing thi...

Page 7: ...hock Exhaust emissions are harmful to health of body No naked fire near the machine This symbol indicates the surface is very hot and not touching 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary acc...

Page 8: ...grip Place one handle on one side of the bar the holes must be aligned Screw it with a screw and a nut Do the same procedure on the other side 4 CONTROLS 4 1 ENGINE SWITCH To start and stop the engin...

Page 9: ...ture when starting a cold engine It can be opened and closed by operating the choke lever or choke rod manually Move the lever or the rod to the CLOSE position to enrich the mixture 4 5 CIRCUIT BREAKE...

Page 10: ...ction must isolate the generator power from utility power and must comply with all applicable laws and electrical codes WARNING Improper connections to a building s electrical system can allow electri...

Page 11: ...rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels between rated and maximum may be used for no more than 30 minu...

Page 12: ...ed battery cable WARNING The battery gives off explosive gases keep spark flames and cigarettes away Provide adequate ventilation when charging or using batteries 2 Connect the positive battery cable...

Page 13: ...carburetor modification is made NOTICE If an engine jetted for high altitude is used at a lower altitude the lean air fuel mixture will reduce performance and may over heat and seriously damage the e...

Page 14: ...prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Use gasoline with a pump octane rating of 86 or higher We recommend unleaded gasoline because it produces fewer engine...

Page 15: ...fuel are not ours responsibility and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spill...

Page 16: ...SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 20 Hrs 3 Every 3 months or 50 Hrs 3 Every 6 months or 100 H...

Page 17: ...and rapid draining 1 Remove the drain plug and sealing washer oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washer Tighten the plug securely 3 Refill with the recommended oil...

Page 18: ...solvent NOTICE Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the elemen...

Page 19: ...ot Be careful not to touch the muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspec...

Page 20: ...E PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add g...

Page 21: ...At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Al...

Page 22: ...he plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap YES YES Is the fuel reaching the carburetor Clean the fuel sediment cup If the engin...

Page 23: ...11 CIRCUIT DIAGRAM...

Page 24: ...kWh Lube Oil capacity L 0 6 L Sound pressure level LpA 74 dB A K 1 99 dB A Measured sound power level LwA 94 4 dB A K 1 99 dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out...

Page 25: ...30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the following technical provisions...

Page 26: ...the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information c...

Page 27: ...epairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456...

Page 28: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Page 29: ...NOTES 22...

Page 30: ...NOTES...

Page 31: ...NOTES...

Page 32: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2021...