background image

 

 

 

1. SAFETY INSTRUCTION    

Warning: 

1. 

Attention! Exhaust gases are toxic. Do not operate the generator in a room without 
ventilation system!

 

2. 

Children should be protected by keeping them at a safe distance from the generator set!

 

3. 

Refilling of the generating sets is not allowed during the operation!

 

4. 

If the generator will be mounted in a closed room, relevant safety regulations against fire and 
explosion should be followed!

 

5. 

Do not connect to household circuit!

 

6. 

Do not use in wet condition!

 

7. 

Keep in flammable away!

 

8. 

 When refueling: 

 

a) 

stop engine;

 

b) 

no smoking;

 

c) 

Do not spill.

 

 

1.1 GENERAL SECURITY INSTRUCTIONS 

  The operator must know the principles of functioning and the structure of the generator and the 

motor. He must know how to stop the motor in case of urgency and how to manipulate the controls. 

  Never let children use this device. 

  Never let people who do not know these instructions use this device. Local regulations may impose 

restrictions on the age of the user. 

  Please do not use this device when people, especially children, or pets are nearby. Direct them 

away from the working area. 

  The operator or the user are responsible for possible accidents or damage to other persons or to 

their property. 

  Do not wear loose clothing or jewellery as this can get caught in the machinery as it runs. 

  Use safety equipment. Wear protective gear such as an anti-dust mask, non-slip safety shoes, and 

a helmet or hearing protection. 

  Stay vigilant, watch what you are doing and show good sense when you use the generator. Do not 

use if you are tired or under the influence of drugs, alcohol or medicines. 

  Install the generator in a place that is well ventilated and make sure that there is at least 1.5 meters 

between the generator and the walls of the building or other equipment. Do not place flammable 

liquids or gases near the generator. 

  Do not run the generator in an enclosed or badly-ventilated space. The exhaust gas from the motor 

contains carbon monoxide which is toxic and may lead to a loss of consciousness or death. 

  Run the generator in 

respect of the power indicated in the user’s manual. Do not run the generator 

with an overload or at excessive speed. 

  The silencer of the generator becomes extremely hot when the motor runs or even for a time after it 

has stopped. Do not touch it as it will burn you. 

  Do not transport or move the generator until it has cooled down. 

Summary of Contents for FG3000-A

Page 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG3000 A USER GUIDE CAUTION Read the instructions before using the product...

Page 2: ...5 GENERATOR USE 10 6 PRE OPERATION CHECK 13 7 STARTING STOPPING THE ENGINE 15 8 MAINTENANCE 16 9 TRANSPORTING AND STORAGE 20 10 TROUBLESHOOTING 22 11 WIRING DIAGRAM 23 12 SPECIFICATIONS 24 13 EC DECLA...

Page 3: ...ing area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get caught in the machinery...

Page 4: ...d cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total length of the extension must not exceed 60m when the section o...

Page 5: ...propriate recipient and sheltered from any sources of fire Carry out filling in a safe place and slowly open the fuel cap to release the pressure which has built up inside the tank Wipe up any drops o...

Page 6: ...o function with a voltage tolerance of 10 or a frequency tolerance of 3 compared with those of the generator 1 5 PROTECTION OF THE ENVIRONMENT You must periodically check the silencer Before doing thi...

Page 7: ...hock Exhaust emissions are harmful to health of body No naked fire near the machine This symbol indicates the surface is very hot and not touching 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary acc...

Page 8: ...grip Place one handle on one side of the bar the holes must be aligned Screw it with a screw and a nut Do the same procedure on the other side 4 CONTROLS 4 1 ENGINE SWITCH To start and stop the engin...

Page 9: ...ture when starting a cold engine It can be opened and closed by operating the choke lever or choke rod manually Move the lever or the rod to the CLOSE position to enrich the mixture 4 5 CIRCUIT BREAKE...

Page 10: ...ction must isolate the generator power from utility power and must comply with all applicable laws and electrical codes WARNING Improper connections to a building s electrical system can allow electri...

Page 11: ...rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels between rated and maximum may be used for no more than 30 minu...

Page 12: ...ed battery cable WARNING The battery gives off explosive gases keep spark flames and cigarettes away Provide adequate ventilation when charging or using batteries 2 Connect the positive battery cable...

Page 13: ...carburetor modification is made NOTICE If an engine jetted for high altitude is used at a lower altitude the lean air fuel mixture will reduce performance and may over heat and seriously damage the e...

Page 14: ...prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Use gasoline with a pump octane rating of 86 or higher We recommend unleaded gasoline because it produces fewer engine...

Page 15: ...fuel are not ours responsibility and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spill...

Page 16: ...SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 20 Hrs 3 Every 3 months or 50 Hrs 3 Every 6 months or 100 H...

Page 17: ...and rapid draining 1 Remove the drain plug and sealing washer oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washer Tighten the plug securely 3 Refill with the recommended oil...

Page 18: ...solvent NOTICE Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the elemen...

Page 19: ...ot Be careful not to touch the muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspec...

Page 20: ...E PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add g...

Page 21: ...At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Al...

Page 22: ...he plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap YES YES Is the fuel reaching the carburetor Clean the fuel sediment cup If the engin...

Page 23: ...11 CIRCUIT DIAGRAM...

Page 24: ...kWh Lube Oil capacity L 0 6 L Sound pressure level LpA 74 dB A K 1 99 dB A Measured sound power level LwA 94 4 dB A K 1 99 dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out...

Page 25: ...30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the following technical provisions...

Page 26: ...the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information c...

Page 27: ...epairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456...

Page 28: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Page 29: ...NOTES 22...

Page 30: ...NOTES...

Page 31: ...NOTES...

Page 32: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2021...

Reviews: