Oxygenated Fuels 

Some gasoline is blended with alcohol or an ether compound to increase the octane. This gasoline 
is  collectively  referred to  as  oxygenated fuels.  Some  areas of the United States use  oxygenated 
fuels  to  help  meet  clean  air  standards.  If  you  use  an  oxygenated  fuel,  be  sure  its  pump  octane 
rating is 86 or higher. 
 

Ethanol (ethyl or grain alcohol) 

Gasoline  containing  more  than  10%  ethanol  by  volume  may  cause  starting  or  performance 
pro

blems. Gasoline containing ethanol may be marketed under the name “Gasohol". 

 
Methanol (methyl or wood alcohol) 

Gasoline  containing  methanol  must  contain  solvents  and  corrosion  inhibitors  to  protect  the  fuel 
system.  Gasoline  containing  more  than  5%  methanol  by  volume  may  cause  starting  and/or 
performance problems and may damage metal, rubber and plastic parts of your fuel system. 
 

MTBE (methyl tertiary butyl ether)

 

You may use gasoline containing up to 15% MTBE by volume. Before using an oxygenated fuel, 
tr

y to confirm the fuel’s contents. Some states (provinces in Canada) require this information to be 

posted on the pump. If you notice any undesirable operating symptoms, switch to a conventional 
unleaded  gasoline.  Fuel  system  damage  or  performance  problems  resulting  from  the  use  of  an 
oxygenated fuel are not ours responsibility and are not covered under warranty. 

NOTICE 
Oxygenated fuels can damage paint and plastic. Be careful not to spill fuel when filling your 
fuel tank. Damage caused by spilled fuel is not covered under warranty. 
 

7. STARTING/STOPPING THE ENGINE  

 

7.1 STARTING THE ENGINE

 

1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start 

if a load is connected. 

2. Turn the fuel valve to the ON position. 
3. Turn the choke lever or to the CLOSE position, or pull the choke rod out to the CLOSE position. 
4. Start the engine 
 

• With recoil starter: 

Turn the engine switch to the ON position. 
Pull the starter grip until compression is felt, then pull briskly. 

 

NOTICE 
Do  not  allow  the  starter  grip  to  snap  back  against  the  engine.  Return  it  gently  to  prevent 
damage to the starter or housing.

 

• With electric starter: (Optional kit) 

Turn the engine switch to the START position and hold it there for 5 seconds or until the engine 
starts. 
 

NOTICE 
Operating the starter motor for more than 5 seconds can damage  the motor.  If the engine 
fails to start, release the switch  and wait 10 seconds before operating the starter again. If 
the  speed  of  the  starter  motor  drops  after  a  period  of  time,  it  indicates  that  the  battery 
should be recharged. 

 
When the engine starts, allow the engine switch to return to the ON position. 
1. Turn the choke lever or push the choke rod to the OPEN position as the engine warms up. 

Summary of Contents for FG3000-A

Page 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG3000 A USER GUIDE CAUTION Read the instructions before using the product...

Page 2: ...5 GENERATOR USE 10 6 PRE OPERATION CHECK 13 7 STARTING STOPPING THE ENGINE 15 8 MAINTENANCE 16 9 TRANSPORTING AND STORAGE 20 10 TROUBLESHOOTING 22 11 WIRING DIAGRAM 23 12 SPECIFICATIONS 24 13 EC DECLA...

Page 3: ...ing area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get caught in the machinery...

Page 4: ...d cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total length of the extension must not exceed 60m when the section o...

Page 5: ...propriate recipient and sheltered from any sources of fire Carry out filling in a safe place and slowly open the fuel cap to release the pressure which has built up inside the tank Wipe up any drops o...

Page 6: ...o function with a voltage tolerance of 10 or a frequency tolerance of 3 compared with those of the generator 1 5 PROTECTION OF THE ENVIRONMENT You must periodically check the silencer Before doing thi...

Page 7: ...hock Exhaust emissions are harmful to health of body No naked fire near the machine This symbol indicates the surface is very hot and not touching 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary acc...

Page 8: ...grip Place one handle on one side of the bar the holes must be aligned Screw it with a screw and a nut Do the same procedure on the other side 4 CONTROLS 4 1 ENGINE SWITCH To start and stop the engin...

Page 9: ...ture when starting a cold engine It can be opened and closed by operating the choke lever or choke rod manually Move the lever or the rod to the CLOSE position to enrich the mixture 4 5 CIRCUIT BREAKE...

Page 10: ...ction must isolate the generator power from utility power and must comply with all applicable laws and electrical codes WARNING Improper connections to a building s electrical system can allow electri...

Page 11: ...rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels between rated and maximum may be used for no more than 30 minu...

Page 12: ...ed battery cable WARNING The battery gives off explosive gases keep spark flames and cigarettes away Provide adequate ventilation when charging or using batteries 2 Connect the positive battery cable...

Page 13: ...carburetor modification is made NOTICE If an engine jetted for high altitude is used at a lower altitude the lean air fuel mixture will reduce performance and may over heat and seriously damage the e...

Page 14: ...prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Use gasoline with a pump octane rating of 86 or higher We recommend unleaded gasoline because it produces fewer engine...

Page 15: ...fuel are not ours responsibility and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spill...

Page 16: ...SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 20 Hrs 3 Every 3 months or 50 Hrs 3 Every 6 months or 100 H...

Page 17: ...and rapid draining 1 Remove the drain plug and sealing washer oil filler cap and drain the oil 2 Reinstall the drain plug and sealing washer Tighten the plug securely 3 Refill with the recommended oil...

Page 18: ...solvent NOTICE Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the element 2 Wash the elemen...

Page 19: ...ot Be careful not to touch the muffler 1 Remove the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspec...

Page 20: ...E PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add g...

Page 21: ...At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Al...

Page 22: ...he plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap YES YES Is the fuel reaching the carburetor Clean the fuel sediment cup If the engin...

Page 23: ...11 CIRCUIT DIAGRAM...

Page 24: ...kWh Lube Oil capacity L 0 6 L Sound pressure level LpA 74 dB A K 1 99 dB A Measured sound power level LwA 94 4 dB A K 1 99 dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out...

Page 25: ...30 EU ROHS Directive EU 2015 863 amending 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the following technical provisions...

Page 26: ...the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information c...

Page 27: ...epairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456...

Page 28: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Page 29: ...NOTES 22...

Page 30: ...NOTES...

Page 31: ...NOTES...

Page 32: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2021...